Follow this procedure when starting-up a new motor installation or when restarting an installation in
which the motor has been removed.

W

Warning

Unintended vehicle or machine movement hazard
When using the RDM in combination with S45 open circuit pumps with LS or EPC be aware that there will

likely be motor movement as long as the engine is turning. Due to the LS-setting of the pump, a standby

pressure will remain in the system even if the normally closed control is fully energized. Lowest standby

pressures to the motor, 15-18 bar or above, may be enough to turn the RDM and has the potential to

cause injury or damage.

Prior to installing the motor, inspect for damage incurred during shipping. Make certain all system
components (reservoir, hoses, valves, fittings, heat exchanger, etc.) are clean prior to filling with fluid.

Start-up procedure

1. Fill the reservoir with recommended hydraulic fluid. Always filter fluid through a 10 micron filter

when pouring into the reservoir. Never reuse hydraulic fluid.

2. Fill the inlet line leading from the pump to the reservoir. Check the inlet line for properly tightened

fittings and be certain it is free of restrictions and air leaks.

3. Fill the pump and motor housing with clean hydraulic fluid. Pour filtered oil directly into the upper

most case drain port.

4. To ensure the pump and motor stay filled with oil, install case drain lines into the upper most case

drain ports.

5. Install a 0 to 35 bar [0 to 500 psi] gauge in the charge pressure gauge port of the pump to monitor

system pressure during start up.

Follow recommendations in the vehicle / machine operator's manual for prime mover start up

procedures.

6. While watching the pressure gauge, jog the prime mover or run at the lowest possible speed until

system pressure builds to normal levels (minimum 11 bar [160 psi]). Once system pressure is

established, increase to full operating speed. If system pressure is not maintained, shut down the

prime mover, determine cause, and take corrective action. Refer to 

Troubleshooting

 on page 14.

7. Operate the hydraulic system for at least fifteen minutes under light load conditions.
8. Check and adjust pump control settings as necessary after installation.
9. Shut down the prime mover and remove the pressure gauge. Replace plug at the charge pressure

gauge port.

10. Check the fluid level in the reservoir; add clean filtered fluid if necessary.

The motor is now ready for operation.

Service Manual

K and L Frame Variable Motors, Cartridge Mount

Initial start-up procedures

 

12 | 

©

 Danfoss | July 2017

520L0631 | AX00000042en-US0402

Содержание K Frame Series

Страница 1: ...Service Manual K and L Frame Variable Motors Cartridge Mount powersolutions danfoss com...

Страница 2: ...morrow 0402 April 2014 Danfoss layout DA July 2013 add anti cavitation valve CB October 2010 new back page CA November 2006 Added loop flushing valve B July 2004 First edition A Service Manual K and L...

Страница 3: ...ure 12 Fluid and filter maintenance Recommendations 13 Troubleshooting Excessive noise and or vibration 14 System operating hot 14 Motor shifting irregularities 14 Minor repair Shaft seal replacement...

Страница 4: ...eginning a service procedure Protect yourself and others from injury Take the following general precautions whenever servicing a hydraulic system W Warning Unintended machine movement Unintended movem...

Страница 5: ...suggestion Lubricate with hydraulic fluid Apply grease petroleum jelly Apply locking compound Inspect for wear or damage Clean area or part Be careful not to scratch or damage Note correct orientation...

Страница 6: ...mum displacement Minimum and maximum displacement can be set with fixed internal stops The large diameter servo piston allows smooth acceleration and deceleration with relatively large circuit orifici...

Страница 7: ...Input shaft Servo piston Displacement control spool Filter High loop pressure Case pressure Charge low loop pressure Control pressure Inlet pressure Charge relief valve Motor displacement control valv...

Страница 8: ...ations Parameter Unit L25 L30 L35 K38 K45 Displacement maximum cm3 in3 25 1 50 30 1 83 35 2 14 38 2 32 45 2 75 Weight cartridge and SAE B kg lb 15 4 34 Mass moment of inertia of rotating components kg...

Страница 9: ...erature C F 40 40 82 180 104 220 Cleanliness ISO 4406 Class 18 13 or better Filtration efficiency suction filtration 35 44 75 10 1 5 charge filtration 15 20 75 10 10 Service Manual K and L Frame Varia...

Страница 10: ...KC LC motors rely on external valving and orificing to regulate shift speeds You can achieve quick acceleration shift to min and slow deceleration shift to max simply by installing an orifice in the...

Страница 11: ...ctions at the locations listed in the table drawing below Recommended gauge sizes are also listed Port information Port identifier Size Pressure obtained Gauge size bar psi X1 0 5625 18 UNF 2B Control...

Страница 12: ...leaks 3 Fill the pump and motor housing with clean hydraulic fluid Pour filtered oil directly into the upper most case drain port 4 To ensure the pump and motor stay filled with oil install case drain...

Страница 13: ...nge the fluid and filter per the vehicle machine manufacturer s recommendations or at these intervals Fluid and filter change interval Reservoir type Max oil change interval Sealed 2000 hours Breather...

Страница 14: ...hanger if so equipped If the heat exchanger fails or becomes obstructed it may not meet the cooling demands of the system Ensure that heat exchanger is receiving adequate air flow and that the heat ex...

Страница 15: ...i P104 251 Install the new shaft seal 1 Cover the shaft splines with an installation sleeve to protect the shaft seal during installation 2 Install a new shaft seal M003 with the cupped side facing t...

Страница 16: ...6 Using a 11 16 in internal hex torque plugs E010 and E020 to 37 N m 27 lbf ft Anti Cavitation Valve Remove the anti cavitation valve The anti cavitation valve is installed into the high pressure por...

Страница 17: ...Lubricate and install new O ring E063 on valve plug E061 3 If needed lubricate and install new O ring E020A on plug E020 4 Using a 5 16 inch internal hex wrench to install valve plug E061 into port w...

Страница 18: ...Service Manual K and L Frame Variable Motors Cartridge Mount Notes 18 Danfoss July 2017 520L0631 AX00000042en US0402...

Страница 19: ...Service Manual K and L Frame Variable Motors Cartridge Mount Danfoss July 2017 520L0631 AX00000042en US0402 19...

Страница 20: ...lutions ApS Nordborgvej 81 DK 6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading S...

Отзывы: