Service guide
Disassembling and assembling iSave 40
8
180R9242 | 521B1213 | DKCFN.PI.003.R3.02 | 04.2016
1.
Place the HP outlet flange on the desk and
mount the O-ring and 2 pins.
2.
Align the port plate-out on the two pins
and mount the O-ring on the port plate.
4.
Assembling the
booster pump
WARNING:
Do not use silicone when assembling the
iSave. Do not reuse disassembled O-rings;
they might be damaged. Always use new
O-rings.
Important:
It is essential that the pump is serviced in
conditions of absolute cleanliness. All parts
must be absolutely clean before mounting.
Lubrication:
•
To prevent seizing-up, lubricate all threads
with PTFE lubrication type.
•
It is important to lubricate ALL parts to be
assembled with clean filtered water
(Especially all PEEK parts).
3.
Turn the stator with the two identification
rings closest to the port plate and position
the stator on the 2 pins.
4.
From down side up and by hand, screw in
two bolts in the stator.