![Danfoss iSave 40 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/danfoss/isave-40/isave-40_service-manual_3535597004.webp)
Service guide
Disassembling and assembling iSave 40
4
180R9242 | 521B1213 | DKCFN.PI.003.R3.02 | 04.2016
7.
Disassemble the bell housing from the
booster pump by unscrewing the 4 bolts in
the bell housing.
8.
It is also possible to disconnect the
complete unit from the motor first. In this
case, please follow step 1, 5, 6 and 7
afterwards.
9.
After the pressure exchanger is released
from the booster pump, remove the two
guide pins.