Service guide
Disassembling and assembling iSave 40
6
180R9242 | 521B1213 | DKCFN.PI.003.R3.02 | 04.2016
6.
Loosen all the bolts in the adapter flange.
7.
Carefully disassemble adapter flange and
port plate from the stator ring.
9.
Remove the 8 vanes.
8.
Remove the sealing plate.
10. Carefully guide the rotor out of the stator.
11. Remove the sealing plate and pin.