Service instruction
Disassembling and assembling iSave 21
12
180R9219 / 521B1171 / DKCFN.PI.003.K3.02 / 11.2013
1.
Gently adjust the spanner wrench around
the coupling and use it as back stop.
3.
Remove all bolts in the HP out connection
flange.
2.
Unscrew the bolt in the middle of the
coupling and remove the coupling.
4.
Remove the flange.
5 .
Disassambling the
vane pump
5.
Remove side plate and pin