Install charge pressure relief valve
52 N•m
[38 lbf•ft]
E101 424E
V10
22 mm
V024
Pressure Limiter Installation
1. Lubricate and install O-rings (L022).
2. Using a 14 mm wrench, install pressure limiter cartridges (L300) and (L400).
3. Torque to 30 N•m [22 lbf•ft].
Refer to Danfoss publication
H1 45/53/60/68 Closed Circuit Axial Piston Pumps Service Manual
520L0958 for instructions on adjusting pressure limiter.
Install pressure limiter
E101 425E
14 mm
L300/L400
30 N•m
[22 lbf•ft]
L022
HPRV Valve Installation
1. Replace and lubricate O-rings (L060) and backup rings (L068) before re-assembly.
2. Using a 22 mm wrench, install HPRV valves (L100) and (L200).
3. Torque to 70 N•m [52 lbf•ft].
Repair Instructions
H1 45/53/60/68 Closed Circuit Axial Piston Pumps
Assembly
520L0957 • Rev CB • September 2014
41