Special
tool
Plug
P108021
Ø 1.7 mm (x3)
Ø 9.22 mm
45 deg.
Ø 14 mm
Screen
Retention
Ring
Drill out retention ring
Remove control
D250
5 mm
(6X)
D150
F00A
3 mm F00B
P106 708E
D610 (2X)
D610A (2X)
Security
wax seal (2X)
D084
D098
D674
D672
Auxiliary Pad or End Cover Removal
Remove auxiliary pump, if present.
1. Position pump so end cover (K100) or auxiliary pad is on top.
2. Remove end cover/auxiliary pad screws (K400) using an 8 mm internal hex wrench.
Alignment pins (G450) are in end cover. They may dislodge during disassembly.
3. Remove and discard gasket (K150).
Repair Instructions
H1 45/53/60/68 Closed Circuit Axial Piston Pumps
Disassembly
520L0957 • Rev CB • September 2014
11