Overview
Wash all parts (including the endcap and housing) thoroughly with clean solvent and allow to air dry.
Blow out oil passages in the housing and endcap with compressed air. Conduct inspection in a clean area
and keep all parts free from contamination. Clean and dry parts again after any rework or resurfacing.
Pistons and Slippers
Inspect the pistons for damage and discoloration. Discolored pistons may indicate excessive heat; do not
reuse.
Inspect pistons
C10
Slipper
Maximum end-play
Minimum
slipper foot
thickness
P106 130E
Inspect the running surface of the slippers. Replace any piston assemblies with scored or excessively
rounded slipper edges. Replace any piston assemblies with excessively worn slippers. Check the slipper
axial end-play. Replace any piston assemblies with excessive end-play.
Minimum slipper foot thickness and maximum axial end-play are given in
ReWork Specifications
520L1033.
Ball Guide, Slipper Retainer, and Hold-Down Pins
Ensure ball guide is free of nicks and scratches, and not scored. Examine for discoloration that may
indicate excessive heat or lack of lubrication. The slipper retainer should be flat, and slippers should fit in
the retainer with minimal side play. Place the hold-down pins on a flat surface and roll them to make sure
they are straight. Discard and replace any damaged parts.
Inspect guide, retainer, and pins
Slipper
retainer
Ball guide
E101 396E
Hold-down pins
C25
C15
C20
Block Spring, and Washers
If cylinder kit was fully disassembled, visual inspection of the cylinder block, spring, and washers should
indicate minimal wear. Replace if cracks or other damage are present.
Repair Instructions
H1 45/53/60/68 Closed Circuit Axial Piston Pumps
Inspection
520L0957 • Rev CB • September 2014
21