Setting up the speed

The electronic control unit FDC1 is supplied 
with the exclusive Serial Port Interface (SPI), 
featuring a RJ11 telephone type connector. This 
port is configured to set up the compressor 
speed through physical connections between 

their terminals. To facilitate this procedure, three 
connector cables are supplied together with the 
electronic driver. The compressor will run at a 
certain speed depending on the used connector, 
as shown in Table 2:

Furthermore, if a FDC programming kit is 
available, the new FDC1 electronic driver can 
be set up by programming it using the kit and a 
computer.

NEVER USE FDC1 ELECTRONIC DRIVER IN OTHER 
DC COMPRESSOR DIFFERENT THAN GD30FDC.

If the compressor or the FDC1 electronic driver 
should be replaced for servicing a refrigerator or 
a freezer, one of the next procedures should be 
followed.

1. If a FDC programming kit is available, use it 
to check the settings of the old FDC1 electronic 
driver and set up the new one by programming 
the same parameters.

2. Otherwise, check the old FDC1 electronic driver 
for the presence of a connector at the SPI to set 
up the speed. If so, take it away and connect it 
again at the new FDC1 electronic driver.

3. Otherwise check the appliance for some 
information about compressor speed set up. If 
so, select the proper connector which gives the 
nearest speed set up from table 2.

4. Otherwise compressor speed can be set up by 
a trial and error procedure. In this case, take as a 
first approximation the connectors indicated in 
table 3 depending on the type of appliance and 
its net volume.

1. Check the compressor model and speed.

2. If speed S

0

 is known and a FDC programming 

kit is available, set up GD30FDC compressor 
speed by programming the following speed:

S = S

0

 / 1.5 for BD35F

S = S

0

 / 1.2 for BD50F

S = S

0

 for BD80F

3. Otherwise, set up GD30FDC compressor speed 
according to Table 4.

Table 2. Compressor 

speed for each connector

Replacing a GD30FDC 

compressor or FDC1 

electronic driver

Replacing a DC 

compressor model 

BD35F, BD50F or BD80F

4. If speed is not known, measure the value of the 
resistor R1 placed in series with the thermostat 

and connected to “C” terminal. Then set up 
GD30FDC speed according to Table 5.

Connector

Speed

NONE

1.500

BLACK

2.167

BLUE

2.833

RED

3.500

Connector

Refrigerator

Freezer

Refrig freezer

None

less than 60 liters

less than 40 liters

less than 50 liters

Black

from 60 to 150 liters

from 40 to 100 liters

from 50 to 125 liters

Blue

from 120 to 300 liters

from 80 to 200 liters

from 100 to 250 liters

Red

from 180 to 450 liters

from 120 to 300 liters

from 150 to 375 liters

Compressor

Without connector

Black connector

Blue connector

Red connector

BD35F

rpm < 2.750

rpm >2.750

-

-

BD50F

rpm < 2.200

rpm = 2.200 a 3.000

rpm > 3.000

-

BD80F

-

rpm < 2.500

rpm = 2.500 a 3.150

rpm > 3.150

Table 3. Suggested 

connector as a the 

function of the appliance

Table 4. Type of 

connector to be used to 

replace Danfoss 

compressor when speed 

is known

6

FRCC.PI.045.A1.02

Содержание GD30FDC

Страница 1: ...Danfoss Light Commercial Refrigeration Compressors GD30FDC Electronic driver connection manual 12 42V Direct Current R134a Installation guide lightcommercialrefrigeration danfoss com ...

Страница 2: ......

Страница 3: ...Content Wiring and Connections 4 Setting up the speed 6 Operating voltage 8 Battery protection system 9 Protections and alarms 10 3 FRCC PI 045 A1 02 ...

Страница 4: ... THE VEHICLE AS WELL AS THE APPLIANCE FRAME A FUSE MUST BE PLACED BETWEEN THE POLE OF THE BATTERY OR DC POWER SUPPLY AND THE POWER INPUT TERMINAL OF THE ELECTRONIC DRIVER 12V SYSTEMS 30A FUSE 24V SYSTEMS 15A FUSE 42V SYSTEMS 10A FUSE In some special vehicles the chassis is connected to terminal of the battery instead of terminal positive reference systems In such cases should be understood as and ...

Страница 5: ...1 Wiring scheme NO RESISTOR IS NEEDED TO BE INSTALLED IN FDC1 ELECTRONIC DRIVER When connecting the electronic driver to the compressor any position of the connector is possible under an electrical point of view However in practice the vertical position is not possible because the electronic box cannot be assembled The connector should be rotated 120 clockwise or counter clockwise with respect to ...

Страница 6: ...compressor speed can be set up by a trial and error procedure In this case take as a first approximation the connectors indicated in table 3 depending on the type of appliance and its net volume 1 Check the compressor model and speed 2 If speed S0 is known and a FDC programming kit is available set up GD30FDC compressor speed by programming the following speed S S0 1 5 for BD35F S S0 1 2 for BD50F...

Страница 7: ...ial an error procedure In this case try the connectors shown in Table 3 depending on the type of appliance and its net volume Replacing a different brand DC compressor Setting up the speed Compressor Without connector Black connector Blue connector Red connector BD35F R1 450 Ω R1 450 Ω BD35F with AEO R1 623 Ω R1 623 Ω BD50F R1 112 Ω R1 112 to 692 Ω R1 692 Ω BD50F with AEO R1 285 Ω R1 285 to 865 Ω ...

Страница 8: ...C power supply DC VOLTAGE SUPPLY ALLOWED is 10V to 42 4V From the value of the applied voltage the electronic driver automatically decides the rated voltage range of the supply Three possible ranges are considered 12 to 14V voltage is below 17V 24 to 28V voltage is within 17 and 33V 36 to 42V voltage is within 33 and 42 4V 8 FRCC PI 045 A1 02 ...

Страница 9: ...protection level is set up for working under normal circumstances in most appliances Cut out and cut in values are 12V system cut out 10 0V cut in 11 5V 24V system cut out 22 0V cut in 24 5V 42V system cut out 36 0V cut in 38 5 V Other values can be set up if a FDC programming kit is available Battery protection system 9 FRCC PI 045 A1 02 ...

Страница 10: ...tions that may cause otherwise refrigeration overload or compressor failure Electronic driver overheat if the temperature of the electronic components of the control becomes too high an internal sensor will stop the unit In case of overheating one automatic attempt to restart the compressor is allowed In case of battery protection there is no limit of automatic attempts to restart In case of any o...

Страница 11: ......

Страница 12: ...d technology specialists Today we operate from engineering and manufacturing facilities spanning across three continents FRCC PI 045 A1 02 Danfoss Light Commercial Refrigeration Compressors made by Huayi Danfoss DCS CC 2016 03 Our products can be found in a variety of applications such as rooftops chillers residential air conditioners heatpumps coldrooms supermarkets milk tank cooling and industri...

Отзывы: