13-40 Logic Rule Boolean 1
Array [6]
Option:
Function:
[82]
Digital input x46/7
[83]
Digital input x46/9
[84]
Digital input x46/11
[85]
Digital input x46/13
13-41 Logic Rule Operator 1
Array [6]
Option:
Function:
Select the first logical operator to use on the
Boolean inputs from
13-40 Logic Rule Boolean
1
and
13-42 Logic Rule Boolean 2
.
[13 -XX] signifies the Boolean input of
parameter group 13-*.
[0]
*
DISABLED
Ignores
13-42 Logic Rule Boolean 2
,
, and
13-44 Logic
Rule Boolean 3
.
[1]
AND
Evaluates the expression [13-40] AND
[13-42].
[2]
OR
evaluates the expression [13-40] OR[13-42].
[3]
AND NOT
evaluates the expression [13-40] AND NOT
[13-42].
[4]
OR NOT
evaluates the expression [13-40] OR NOT
[13-42].
[5]
NOT AND
evaluates the expression NOT [13-40] AND
[13-42].
[6]
NOT OR
evaluates the expression NOT [13-40] OR
[13-42].
[7]
NOT AND NOT evaluates the expression NOT [13-40] AND
NOT [13-42].
[8]
NOT OR NOT
evaluates the expression NOT [13-40] OR
NOT [13-42].
13-42 Logic Rule Boolean 2
Array [6]
Option:
Function:
[0]
*
FALSE
Select the second Boolean (TRUE or
FALSE) input for the selected logic
rule. See
([0] - [61])
and
([70] - [75]) for
further description.
[1]
TRUE
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Mains out of range
[18]
Reverse
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
[28]
Logic rule 2
[29]
Logic rule 3
[30]
SL Timeout 0
[31]
SL Timeout 1
[32]
SL Timeout 2
[33]
Digital input DI18
[34]
Digital input DI19
[35]
Digital input DI27
[36]
Digital input DI29
[37]
Digital input DI32
[38]
Digital input DI33
[39]
Start command
[40]
Drive stopped
[41]
Reset Trip
[42]
Auto-reset Trip
[43]
OK key
Parameter Descriptions
FC 300 Programming Guide
3-114
MG.33.MA.22 - VLT
®
is a registered Danfoss trademark
3
3