FC 300 Profibus
Application Examples
E.g.: PLC Programming
In this example PPO type 6 is placed in the following Input/Output address:
Input
address
256-257
258-259
260-261
262-263
Output
address
256-257
258-259
260-261
262-263
Set-up
Status
word
MAV
Motor
torque
Digital
input
Set-up
Control
word
Reference
Not used
Not used
This network will send a start command (047C Hex)
and a reference (2000 Hex) of 50% to the FC 300.
This network reads the motor torque from the FC
300 drive. A new reference will be sent to the FC
300 drive because the Motor Torque (86.0%) is
higher than the compared value.