7
Troubleshooting
Error
Cause
Remedy
Machine does not cut
Main switch is off
Switch on the main switch.
Power plug defective
Check the power plug,
replace if necessary.
Motor defective
Contact service.
Main switch defective
Contact service.
Cutting knife worn
Check cutting knife for wear,
replace if necessary.
Knife not centred
Flange disc is not positioned
correctly on the feather key
Turn flange disc and insert it
into the feather key.
Pneumatic feed is not working.
Compressed air supply dis-
connected.
Connect compressed air.
Air pressure too low.
Check air pressure and in-
crease, if required.
Work piece is jammed in knife
protection.
Deactivate the machine on the
main switch and secure it
against unintentional restart.
Open the protective cover. Re-
move the work piece. Wear
cut-proof gloves.