2.
Fit the supply line of the power cable with a battery
disconnection switch.
3.
Connect the power cable to the + positive terminal (2) and the -
negative terminal (1).
4.
Connect the plug (3) of the hydraulic unit to the socket of the
machine back.
For interrupting the battery power supply, a main power switch is
to be installed in the working area of the machine in accordance
with accident prevention regulations.
Make sure that the power cable has been installed correctly and
properly. Improper installation may result in excessive heating of
the connection terminals and the power cable.
A minimum of 88 Ah battery power of the vehicle is required. Do
not use any gel batteries.
In order to prevent the battery from being discharged, the hydraulic
unit should only be started when the vehicle engine is running.
ATTENTION!
Risk of damage to machinery!
The hydraulic power unit is not rated for permanent operation.
• The maximum of 30 crimping cycles per hour must not be
exceeded.
4.3.4 Bleeding the hydraulic system
1.
Switch on the machine.
2.
Operate the machine in the idle mode for two minutes in order to
fill the pump with oil.