Figure 27. Shrink tube
8. Insert the cable through the corresponding hole in the connection box and connect the cable
lug to the connection point. Use spring washer between the cable lug and the connection screw
or nut. Example of the connection is shown in Figure below. Do not tighten the connection at this
point to ensure tting of the cable gland.
Make sure that there is at least 10 mm air gap between the cable lug and other metallic structures including the braid of
the cable. If the air gap is smaller, use extra insulation shrink tube to cover the lug.
Figure 28. Cable lug connection to the connection box (example only, the connection box may look
different)
9. Screw the cable gland to the connection box as shown in Figure below. Tighten the cable gland
from the cap of the gland. See Chapter
Tightening torques
.
EM-PMI540-T1500
6. Installation
| BC265856800806en-000106
©
Danfoss | Produced By: Danfoss Power Solutions | January 2019 | 39