Mounting Instructions

Please observe the following placement guidelines:

Place the thermostat at a suitable height on the wall 
(typically 80-170 cm.).

The thermostat should not be placed in wet rooms. 
Thermostat must be placed outside zone 2. Place it 
in an adjacent room and use floor sensor only.  
Always place the thermostat according to local 
regulation on IP classes.

Do not place the thermostat on the inner side of a 
poorly insulated exterior wall.

Always install the thermostat at least 50 cm from 
windows and doors, due to draft, when using regu-
lation in: floor and room mode or room alone mode.

Do not place the thermostat in a way that it will be 
exposed to direct sunlight.

Содержание ECtemp Smart

Страница 1: ...heating danfoss com new solutions ectemp smart Danfoss ECtemp Smart Intelligent Electronic Timer Thermostat with Wi Fi connectivity and App control Installation Guide...

Страница 2: ...signed for fixed installation only and can be used for both direct heating of the entire room and for comfort heating of the floor Among others the thermostat has the following features 1 Introduction...

Страница 3: ...tings can be specified before instal lation and imported to the thermostat using a web generated code or copied from a thermostat in a similar installation Smart access to thermostat settings after in...

Страница 4: ...0 V 50 60 Hz Standby power consumption Max 0 40 W Relay Resistive load Inductive load Max 16 A 3680 W 230 V Max 1 A cos 0 3 Sensing units NTC 6 8 kOhm at 25 C NTC 10 kOhm at 25 C NTC 12 kOhm at 25 C N...

Страница 5: ...up to 45 C Min floor 10 35 C only with combination of room and floor sensor Sensor failure monitoring The thermostat has a built in monitoring circuit which will switch off the heating if the sensor...

Страница 6: ...IEC Standard Automatic electrical controls for household and similar use EN IEC 60730 1 general EN IEC 60730 2 9 thermostat 3 Safety Instructions Make sure the mains supply to the thermostat is turne...

Страница 7: ...hermostat to moisture water dust and excessive heat This thermostat can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of expe...

Страница 8: ...placed outside zone 2 Place it in an adjacent room and use floor sensor only Always place the thermostat according to local regulation on IP classes Do not place the thermostat on the inner side of a...

Страница 9: ...ensor in a protecting plastic conduit in the floor construction in an appropriate place where the floor is not exposed to sunlight or draft from door openings Equally distant and 2 cm from the heating...

Страница 10: ...install the floor sensor in a conduit in the floor 3 Fasten the thermostat firmly to a flush mounted wall box or an exterior wall box by driving the screws through the holes in each side of the thermo...

Страница 11: ...stat Important Do NOT press in the center of the display screen Press your fingers under the side of the front part and pull toward you until it releases from the snap lock To ensure that the batterie...

Страница 12: ...onalities are to support user interface through display and hold all the controller logic Display main functionalities are to show the current status of the Thermostat and recognize the user actions f...

Страница 13: ...comma separator Symbol indications Indication Mode State Description Blue blinking Access Point Mode Thermostat ready for set up Blue Access Point Mode Smart phone connected directly to thermostat fo...

Страница 14: ...irectly on thermostat Function Button Description Turn thermo stat on 1 Touch any button 2 Touch control button 1 Thermostat switch on and display temperature Turn thermo stat off 1 Touch any button 2...

Страница 15: ...activate safety lock Factory restore Touch and hold Control 1 Up 2 for 5 sec After that touch Control 1 again to confirm Activates factory restore state Away mode Touch and hold Control 1 for 1 sec to...

Страница 16: ...cuited E2 Sensor short circuited Contact service The thermostat requires a restart to operate again Ther mostat over heated E3 Thermostat is over heated heating is turned off Wait until ther mostat co...

Страница 17: ...rror Codes Communication error Nr Description Wrong SSID or password C1 STA trying to connect to the AP No IP address C2 STA connection acquired no IP yet waiting for configuration data No internet co...

Страница 18: ...etwork administrator or internet service provider Identify your floor sensor type in kOhm Identify your installed heating output inW from label on the heating element Power on the thermostat and it wi...

Страница 19: ...room only option is also avail able but requires that you have to break the small plastic seal on the back of the display module e g us ing a screwdriver it will be possible to set the maximum floor...

Страница 20: ...set the maximum floor temperature to more than 35 C Note Please contact the floor supplier before changing the maximum floor temperature and be aware of the following The floor temperature is measured...

Страница 21: ...g Details kg m3 Approximate setting for 25 C floortemperature 0 05 8 mm HDF based laminate 800 28 C 0 10 14 mm beech parquet 650 800 31 C 0 13 22 mm solid oak plank 800 32 C 0 17 Max carpet thick ness...

Страница 22: ...o a manufacturing defect in the Danfoss product be repaired or replaced free of charge To apply for this warranty the installation must be performed by an authorized installer and the warranty certifi...

Страница 23: ...Danfoss ECtemp Smart 23 Installation Guide...

Страница 24: ...material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being n...

Отзывы: