![background image](http://html1.mh-extra.com/html/danfoss/dm430e-series/dm430e-series_user-manual_3426125007.webp)
Up to four signals can be monitored on each screen. Use the EIC software to configure the DM430E for
alarms and alerts.
Navigation using soft keys
The DM430E is controlled by navigation through a set of four soft keys located at the lower front of the
display. The keys are context dependent. Soft key selection options are displayed above each key and are
dependent on the current navigation location within the engine monitor software program. As a general
rule, the far right soft key is the selector button and the far left soft key is the step back one screen key. To
optimize full screen use, the on-screen selections are not displayed when not in use. Press any soft key to
display current selection options.
Navigation using soft keys
Inhibit
Switch
Initiate
Switch
TSC1RPM
Set Point
Exit/Back
One Screen
Exit/Back
One Screen
Navigate
Up
Navigate
Down
Select
Next
Menu
Navigate
Up
Navigate
Down
Main
Menu
Decrement
Increment
Screen navigation
Navigate Up
Press to move up through menu items or screens
Navigate Down
Press to move down through menu items or screens
Main Menu
Press to go to Main Menu screen
Exit/Back one screen
Press to go back one screen
Select
Press to accept selection
Next Menu
Press to select next digit or screen element
Inhibit Regen
Press to force regeneration of particulate filter
Initiate Regen
Press to inhibit particulate filter regeneration
Increment/decrement
Press to increment or decrement value
Initiate and inhibit regeneration
While EIC DM430E is displaying one of the monitor screens, pressing any soft key will show the available
navigation actions in an action menu. There are two separate action menus on this level, the first one to
appear contains the following actions (from left to right).
•
Next Menu
•
Navigate Up
•
Navigate Down
•
Main Menu
Selecting Next Menu will display the second action menu with Inhibit switch (Inhibit Regeneration),
Initiate switch (Initiate Regeneration) and RPM Set Point. Pressing it again will show the first set of
actions once more. Selecting Navigate Up and Navigate Down will allow navigation between signal
monitoring screens. Selecting Main Menu will display the DM430E set up options. If no soft keys are
pressed and released for 3 seconds while the action menu is shown, the menu will disappear and the
actions are no longer available. Pressing (and releasing) any soft key will activate the first menu once
more.
User Manual
DM430E Series Display - Engine Information Center (EIC) Software
Overview
©
Danfoss | December 2018
AQ288937102741en-000102 | 7