9
Important information/Safety regulation
9.1
General safety precautions
Warning
Risk of personal injury! Children are not permitted to play with the product.
Warning
As the water temperature in DHP-H Opti Pro and DHP-L Opti Pro becomes extremely hot, a mixer valve must
be installed between the cold water and hot water pipes to ensure a lower domestic hot water temperature.
Alternatively the maximum hot water temperature must be reduced in the Service menu.
Warning
Danfoss SP (1-phase) heat pumps have a factory installed safety valve for temperature and pressure, (10 bar
90-95°C), in accordance with the requirements in Great Britain. This valve is located in the water tank and may
not be used for any purpose other than connecting the outlet pipe. Also note that for heat pump DHP-H Opti
Pro SP and DHP-L Opti Pro SP it is imperative that the hot water temperature is changed from default setting
95°C to 85°C.
Caution
The heat pump must be installed by authorised installation engineers and the installation must follow the
applicable local rules and regulations as well as these installation instructions.
Caution
This product is not intended for persons (including children) with reduced physical, sensory or psychological
capacity, or who do not have knowledge or experience, unless supervised or they have received instructions
on how the apparatus functions from a safety qualified person.
Caution
The heat pump must be located in a frost-free environment!
Caution
The heat pump must be placed in an area with a floor drain.
Caution
The heat pump must be located on a stable base. The floor must be able to support the gross weight of the
heat pump with filled hot water tank (see Technical data).
Caution
To prevent leaks, ensure that there are no stresses in the connecting pipes!
Caution
It is important that the heating system is bled after installation.
Caution
Bleed valves must be installed where necessary.
Commissioning
Danfoss Heating Solutions
VIGFH102
27