4. Load the pump's outlet pressure to 50 bar and input 400mA to electric displacement control, then
loosen the electric displacement control lock nut and turn its adjusting screw until the pump
table below), which can calculated by monitoring pump
outlet flow and pump speed. Clockwise turning adjusting screw decrease pump displacement,
counterclockwise turning increase pump displacement. The displacement - current curve will offset
(see
5. While holding the position of the electric displacement control adjusting screw, torque the lock nut
to 9.5 N•m [84 lbf•in].
6. Test another current value. Input 500 mA to electric displacement control, check if the displacement
is within the range specified in the below table at this moment. If it is, the electric displacement
control adjustment complete, if it is not, please re-adjust.
7. Stop the prime mover, remove the pressure gauge and flow meter, and return the system to its
normal operating configuration.
Displacement
Input Current
Size 130
Size 145
Size 193
Size 260
400mA+/-8 mA
67.5cc+/-5cc
67.5cc+/-5cc
92.5 cc+/-5cc
140.5 cc+/-5cc
500mA+/-8 mA
101cc+/-5cc
101cc+/-5cc
115.5 cc+/-5cc
172.5 cc+/-5cc
Service Manual
D1 High Power Open Circuit Pumps Size 65/130/145/193/260
Adjustments
©
Danfoss | July 2019
L1527453 | AX00000292en-CN0201 | 37