7
VI.UH.P1.52
Produced by Danfoss Floor Heating Hydronics 08.008
Instruction CF-RP Public (Tamperproof) Room Thermostat
Note:
•
To activate batteries in the Room Thermostat
please remove enclosed strips from the batteries
•
The assignment of the Room Thermostats to the
Master Controller should be within 1½m distance
Activate Install mode on
Master Controller - fig. 1
• Use the menu selection button to select the
Install mode. Install LED
flashes
• Activate Install mode by pressing OK . Install
LED goes ON
Activate Install mode on
Room Thermostat
• Press the push button . LED
and flicker
during communication
Select output on Master Controller
• All available output LEDs on Master Controller
light up, and the first of them flashes
• Press output selection button , select desired
output (flashes) and accept with OK
• All output LEDs go OFF. Selected output
stays ON shortly
2. Installation