background image

6

VI.UH.P1.52

Produced by Danfoss Floor Heating Hydronics 08.008

Instruktion CF-RP Rumthermostat - Institutionsmodel

Frontdæksel - fig. 3

  Udløs frontdæksel

Содержание CF-RP 088U0211

Страница 1: ...n CF RP Public Tamperproof Room Thermostat Anleitung CF RP ffentlicher Raumthermostat gegen Eingriffe gesichert Instruktion CF RP Rumthermostat Institutionsmodel Instruction CF RP Thermostat collectiv...

Страница 2: ...VI UH P1 52 Produced by Danfoss Floor Heating Hydronics 08 2008 Instruction CF RP Public Tamperproof Room Thermostat...

Страница 3: ...Instruction 3 Anleitung 14 Vejledning 25 Instruction 34...

Страница 4: ...Hydronics 08 2008 Instruction CF RP Public Tamperproof Room Thermostat 1 Functional Overview 5 2 Installation 7 3 Transmission Test 9 4 Mounting 10 5 Uninstallation 11 6 Specifications 12 7 Troublesh...

Страница 5: ...button room tempera ture setting installation transmission test LED modes Permanent light ON No light OFF Slow flashing Flashes Fast flashing Flickers Back fig 2 Back plate Front cover release Back pl...

Страница 6: ...VI UH P1 52 Produced by Danfoss Floor Heating Hydronics 08 2008 Instruction CF RP Public Tamperproof Room Thermostat Front Cover fig 3 Front Cover release...

Страница 7: ...on Master Controller fig 1 Use the menu selection button to select the Install mode Install LED flashes Activate Install mode by pressing OK Install LED goes ON Activate Install mode on Room Thermost...

Страница 8: ...ing Hydronics 08 2008 Instruction CF RP Public Tamperproof Room Thermostat Room Thermostat installation status Satisfactory LED goes OFF Not satisfactory LED flashes 5 times Note A Room Thermostat can...

Страница 9: ...on LED goes ON Link test is satisfactory LED goes OFF Link test is unsatisfactory LED flashes 5 times No Link connection to Room Thermostat Try to relocate Room Thermostat in the room Or install Repea...

Страница 10: ...Instruction CF RP Public Tamperproof Room Thermostat Placing the Room Thermostat fig 4 Wherever possible the room thermostat should be installed at a place where the effect of sunlight draught other h...

Страница 11: ...e Uninstall mode on Master Controller fig 1 Use the Menu selection button to choose the Uninstall menu Uninstall LED flashes Activate Uninstall mode by pressing OK Uninstall LED goes ON Deselect outpu...

Страница 12: ...blic Tamperproof Room Thermostat Temperature setting range 5 35 C Transmission frequency 868 42MHz Transmission range in normal buildings up to 30m Transmission power 1mW Battery Alkaline 2xAA 1 5V Ba...

Страница 13: ...08 2008 Instruction CF RP Public Tamperproof Room Thermostat Error Indication Possible Cause The LED flashes every 5th minute Low battery The LED flashes Critical low battery The LED flashes 5 times...

Страница 14: ...2008 Anleitung CF RP ffentlicher Raumthermostat gegen Eingriffe gesichert 1 Funktions bersicht 15 2 Installation 17 3 Funk Verbindungstest 19 4 Montage 20 5 Deinstallation 21 6 Technische Daten 22 7...

Страница 15: ...Raumtemperatur und Funk Verbindungs test LED Anzeige Dauerlicht EIN Kein Licht AUS Langsames Blinken Blinkt Schnelles Blinken Flackert R ckseite Abb 2 Hintere Abdeckung L sevorrichtung des Drehknopfe...

Страница 16: ...16 VI UH P1 52 Produced by Danfoss Floor Heating Hydronics 08 2008 Anleitung CF RP ffentlicher Raumthermostat gegen Eingriffe gesichert Vordere Abdeckung Abb 3 L sevorrichtung der vorderen Abdeckung...

Страница 17: ...olgen Aktivieren Sie den Installationsmodus am Hauptregler Abb 1 Verwenden Sie die Taste zur Men auswahl um den Installationsmodus zu w hlen Der Installations LED blinkt Aktivieren Sie den Installatio...

Страница 18: ...r Ausgangswahl w hlen Sie den gew nschten Ausgang blinkt und best tigen Sie mit OK Alle Ausgangs LED s wechseln zu AUS Der gew hlte Ausgang wechselt kurz zu EIN Installationsstatus des Raumthermo stat...

Страница 19: ...echselt zu AUS Der Verbindungstest ist nicht ok Die LED blinkt 5 Mal Keine Verbindung zum Raumthermo staten Abhilfe Ver ndern Sie die Position des Raumthermo staten im Raum Installieren Sie den Signal...

Страница 20: ...RP ffentlicher Raumthermostat gegen Eingriffe gesichert Platzieren des Raumthermostaten Abb 4 Sofern m glich sollte der Raumthermostat an ei nem Ort ohne Sonneneinstrahlung Luftzug andere W rmequellen...

Страница 21: ...rwenden Sie die Taste zur Men auswahl um den Deinstallationsmodus zu w hlen Die Deinstallations LED blinkt Aktivieren Sie den Deinstallationsmodus indem Sie auf OK dr cken Die Deinstallations LED wech...

Страница 22: ...icher Raumthermostat gegen Eingriffe gesichert Temperaturbereich 5 35 C Sendefrequenz 868 42MHz Sendebereich in nor malen Geb uden bis zu 30m Sendeleistung 1mW Batterie Alkaline 2xAA 1 5V Lebensdauer...

Страница 23: ...ffentlicher Raumthermostat gegen Eingriffe gesichert Fehleranzeige M gliche Ursache Die LED blinkt alle 5 Minuten Batterieladezustand niedrig Die LED blinkt Batterieladezustand u erst niedrig Die LED...

Страница 24: ...ng Hydronics 08 2008 Instruktion CF RP Rumthermostat Institutionsmodel 1 Funktionsoversigt 25 2 Installation 27 3 Transmissionstest 29 4 Montering 30 5 Afinstallation 31 6 Specifikationer 32 7 Fejlfin...

Страница 25: ...knap indstilling af rumtem peratur og installations transmissions test Lysdiode Aktivitet Konstant lys T ndes Lyser ikke Slukkes Langsom blinken Blinker Hurtig blinken Flimrer Bagside fig 2 Bagplade U...

Страница 26: ...26 VI UH P1 52 Produced by Danfoss Floor Heating Hydronics 08 2008 Instruktion CF RP Rumthermostat Institutionsmodel Frontd ksel fig 3 Udl s frontd ksel...

Страница 27: ...p menuknappen for at v lge Install Install lysdioden blinker Tryk p OK for at aktivere Install Install lys dioden t ndes Aktivering af tilstanden Install p rumtermostaten Tryk p knappen Lysdioderne o...

Страница 28: ...08 2008 Instruktion CF RP Rumthermostat Institutionsmodel Rumtermostatens installationsstatus Tilfredsstillende lysdioden slukkes Ikke tilfredsstillende lysdioden blinker fem gange Bem rk En rumtermo...

Страница 29: ...ilfredsstillende Lysdioden slukkes Linktesten er ikke tilfredsstillende Lysdioden blinker fem gange Ingen linkforbindelse til rumtermo staten Pr v at ndre rumtermostatens placering i rummet Eller inst...

Страница 30: ...nics 08 2008 Instruktion CF RP Rumthermostat Institutionsmodel Placering af rumtermostaten fig 4 Rumtermostaten skal s vidt muligt installeres hvor p virkningen fra sollys tr k andre varme kilder f ek...

Страница 31: ...nstall p master regulatoren fig 1 Tryk p menuknappen for at v lge Uninstall Uninstall lysdioden flimrer Tryk p OK for at aktivere Uninstall Uninstall lysdioden t ndes Fravalg af udgang p masterregula...

Страница 32: ...mostat Institutionsmodel Temperatur indstilling somr de 5 35 C Transmissionsfrekvens 868 42MHz Transmissionsr k kevidde i almindelige bygninger op til 30m Transmissionseffekt 1mW Batteri Alkaline 2xAA...

Страница 33: ...ruktion CF RP Rumthermostat Institutionsmodel Fejlindikation Mulig rsag Indikatoren blinker hvert femte minut Batteriniveau lavt Indikatoren blinker Batteriniveau kritisk lavt Indikatoren blinker fem...

Страница 34: ...onics 08 2008 Instruction CF RP Thermostat collectivites r glage masqu 1 Pr sentation des fonctions 35 2 Installation 37 3 Test de transmission 39 4 Montage 40 5 D sinstallation 41 6 Sp cifications 42...

Страница 35: ...ature pi ce test installation trans mission Modes diode LED Toujours allum MARCHE teint ARR T Clignotement lent Clignotant Clignotement rapide Scintillant Arri re fig 2 Plaque arri re lib rer le couve...

Страница 36: ...36 VI UH P1 52 Produced by Danfoss Floor Heating Hydronics 08 2008 Instruction CF RP Thermostat collectivites r glage masqu Couvercle avant fig 3 Lib rer couvercle avant...

Страница 37: ...incipal ne doit pas se faire plus de 1 m de distance Activer le mode installation sur le R gulateur principal fig 1 Utiliser le bouton de s lection menu pour s lectionner le mode Installation La diode...

Страница 38: ...al s allument et la premi re clignote Appuyer sur le bouton de s lection sortie s lectionner la sortie d sir e clignotements et accepter avec OK Toutes les diodes LED de sortie s teignent La sortie s...

Страница 39: ...test de transmission est satisfai sant La diode LED s teint Le test de transmission n est pas de lete satisfaisant La diode LED clignote 5 fois Absence de transmission radio Essayer de d placer le The...

Страница 40: ...ruction CF RP Thermostat collectivites r glage masqu Emplacement du Thermostat d ambiance fig 4 Installer si possible le thermostat d ambiance un endroit non expos au soleil aux courants d air et d au...

Страница 41: ...ig 1 Utiliser le bouton de s lection Menu pour s lectionner le menu D sinstallation La diode LED D sinstallation clignote Activer le mode D sinstallation en appuyant sur OK La diode LED D sinstallatio...

Страница 42: ...ivites r glage masqu Gamme de r glage temp rature 5 35 C Fr quence transmission 868 42MHz Port e transmission dans des immeubles normaux jusqu 30m Puissance transmission 1mW Piles Alkaline 2xAA 1 5V D...

Страница 43: ...on CF RP Thermostat collectivites r glage masqu Indication erreur Cause possible La diode LED clignote toutes les 5 minutes Piles faibles La diode LED clignote Piles tr s faibles La diode LED clignote...

Страница 44: ......

Страница 45: ...Fig 1 Fig...

Страница 46: ...g 2 Fig 3 Fig 4...

Страница 47: ...1 5 m...

Страница 48: ...088N2462 08 2005 Version 01...