4.9.12 - CONFIG menu

NAME

DESCRIPTION

GEN_CONF

General configuration menu

PUMPCONF

Water pump configuration menu

HC_CONFIG

Heating/cooling configuration menu

HDC_CONF

Heating module configuration menu

RESETCFG

Reset configuration menu

USERCONFIG

User configuration menu

SCHEDULE

Time schedule

HOLIDAY

Holiday calendar

BRODCAST

Broadcast menu

DATETIME

Date and time menu

DISPLAY

Display configuration menu

CTRL_ID

Identification control

4.9.13 - ALARMRST menu

NAME

FORMAT

UNIT

DESCRIPTION

RESET_AL

Normal

-

Alarm reset 

ALM

Normal

-

Alarm status

alarm_1c

nnnnn

-

Current alarm 1

alarm_2c

nnnnn

-

Current alarm 2

alarm_3c

nnnnn

-

Current alarm 3

alarm_4c

nnnnn

-

Current alarm 4

alarm_5c

nnnnn

-

Current alarm 5

alarm_1

nnnnn

-

Current JBus alarm 1

alarm_2

nnnnn

-

Current JBus alarm 2

alarm_3

nnnnn

-

Current JBus alarm 3

alarm_4

nnnnn

-

Current JBus alarm 4

alarm_5

nnnnn

-

Current JBus alarm 5

4.9.14 - CUR_ALRM menu

This menu lists up to ten a active alarms. For each alarm the 

display shows the time and date the alarm was generated as 

well as the alarm description. Each screen shows one alarm.

…\ALARMS\CUR_ALM

HH:MM DD-MM-YY: alarm text

Alarm #1

4.9.15 - ALMHIST1 menu

This menu lists up to twenty alarms that have occurred at the 

unit. For each alarm the display shows the time and date the 

alarm was generated as well as the alarm description. Each 

screen shows one alarm.

…\ALARMS\ALMHIST1

HH:MM DD-MM-YY: alarm text 

Alarm #1

4.9.16 - SCHEDULE menu

NAME

DESCRIPTION

OCC1P01S

Unit on/off time schedule

OCC1P02S

Unit setpoint selection time schedule

OCC3P03S 

Domestic hot water time schedule

4.9.17 - HOLIDAY menu

NAME

DESCRIPTION

HOLDY_01

Holiday period 1

HOLDY_02

Holiday period 2

HOLDY_03

Holiday period 3

HOLDY_04

Holiday period 4

HOLDY_05

Holiday period 5

HOLDY_06

Holiday period 6

HOLDY_07

Holiday period 7

HOLDY_08

Holiday period 8

HOLDY_09

Holiday period 9

HOLDY_10

Holiday period 10

HOLDY_11

Holiday period 11

HOLDY_12

Holiday period 12

HOLDY_13

Holiday period 13

HOLDY_14

Holiday period 14

HOLDY_15

Holiday period 15

HOLDY_16

Holiday period 16

Содержание BW10 020-090

Страница 1: ...BW10 020 090 Control Operation instructions VMGFU102...

Страница 2: ...AL FEATURES 6 4 2 Default screen characteristics 6 4 3 Password screens 6 4 4 Menu screen characteristics 6 4 5 Data screen or configurable parameter characteristics 6 4 6 Parameter modification 7 4 7...

Страница 3: ...2 GENERAL DESCRIPTION 2 1 General The BW10 unit has one refrigerant circuit with one or two compressors The unit has an electronic control system to regulate water cooled units with or without hydron...

Страница 4: ...ctronic sensors are used to measure the suction and the discharge pressure of the water pump The water flow rate is calculated the unit is protected against water flow losses and the pump is protected...

Страница 5: ...lowing table summarises the connections at the user terminal block NRCP2 BASE control board Optional PD AUX board J2A J2B J3 J4 J12 J3 3 6 2 Volt free contact on off cooling heating If the unit works...

Страница 6: ...rd entry screen 0_ Password value 0 basic access Description The password is entered digit by digit The cursor is shown at the current digit that flashes The arrow keys modify the digit value The digi...

Страница 7: ...cessible for the first selected character Modify value Description of the screen csp 2 12 0 C Current value 11 5_ C New value before validation Cooling Setpoint 2 Item description The value is validat...

Страница 8: ...UMPCONF HCCONFIG RESETCFG USERCONF SCHEDULE HOLIDAY BRODCAST DATETIME CTRL_ID OCC3P03S HCCONFIG HDC_CONF HOLIDY16S HOLIDY02S HOLIDY01S PUMPSTAT HDC_STAT OCC1P01S OCC2P02S 4 8 Menu tree structure NAVIG...

Страница 9: ...emperature evaporator HTWSTEMP nnn n C Common master slave temperature condenser DGT A nnn n C Discharge gas temperature A SCT_A nnn n C Saturated condensing temperature A SST_A nnn n C Saturated suct...

Страница 10: ...ibration Following a water pressure sensor error CL_OFFST is deconfigured 99 kPa to inform of the need to calibrate the water loop This calibration must be made while there is no water flow in the mac...

Страница 11: ...hours compressor B1 st_cp_b1 nnnnn Number of start ups compressor B1 HR_CP_B2 nnnnn hours Operating hours compressor B2 st_cp_b2 nnnnn Number of start ups compressor B2 hr_clpmp nnnnn hours Operating...

Страница 12: ...up to ten a active alarms For each alarm the display shows the time and date the alarm was generated as well as the alarm description Each screen shows one alarm ALARMS CUR_ALM HH MM DD MM YY alarm te...

Страница 13: ...No Yes Yes Flow rate verification when the pump has shut down cdpmpseq No Yes No Condenser pump selection cdpmpper No Yes No Condenser pump seizure protection cdpmpsby No Yes No Pump shutdown when the...

Страница 14: ...Bus number baudrate 9600 to 38400 9600 Communication speed PRO DIALOG 30WG Description CSA SR 20H450NN Software version Serial number 4 9 27 OCCx P0xS menu The control provides three timer programs s...

Страница 15: ...ek MTWTFSSH Monday Tuesday Wednesday Thursday Friday Saturday Sunday Holiday OCCTOD4 0 00 24 00 00 00 Occupied from UNOCTOD4 0 00 24 00 00 00 Occupied until DOW5 0 1 0 Period 5 days of the week MTWTFS...

Страница 16: ...tically on a unit with outside air temperature sensor In automatic mode the outdoor temperature determines the heating cooling standby changeover based on the two threshold values configured by the us...

Страница 17: ...ature is controlled by default but the heat exchanger leaving water temperature can also be controlled requires a Service configuration modification Control point active setpoint reset 5 5 1 Active se...

Страница 18: ...r withdraw a capacity stage If the same compressor undergoes too many starts per hour or runs below one minute each time it is started this automatically brings about reduction of compressor starts wh...

Страница 19: ...ntacts if the unit has been configured for remote control One of the functions of the master unit depending on its configuration may be the designation whether the master or slave is to be the lead ma...

Страница 20: ...tank request contact is open OR The maximum operating duration in the DHW mode has finished OR Time schedule 3 is in an unoccupied period If a mode change is requested while a compressor is operat in...

Страница 21: ...omatic when communication is re established Installation bus fault or defective slave board Depending on the configuration compressor A3 is shut down or circuit B is shut down 22 Co e1 Communication l...

Страница 22: ...ove As above 55 P62 2 Evaporator water loop control fault missing sensor calibration Automatic if the calibration is valid No calibration As above P62 3 Water loop control fault suction pressure too l...

Страница 23: ...23...

Страница 24: ...VMGFU102...

Отзывы: