44
180R9263 / IOM APP 5.1-10.2 Appendices - v02 / 01.2013
Instruction
Trouble shooting guide for APP pumps
10
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice.
This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Danfoss A/S
High Pressure Pumps
DK-6430 Nordborg
Denmark
Picture 1
If the port plate has scratches, level differences or both between the arrows,
the port plate must be replaced.
Even small scratches or wear will cause loss of flow.
To check: See item 6.1, picture 3
6.2 Port plate
6.3 Swash plate
Picture 1
If the swash plate is polished 360°, it is an indication of insufficient filtration.
The surface of the swash plate must be plane and even at same level all
over. To check this, please see item 6.1, picture 3.
If the surface has any marks/scratches it is worn/damaged and a new one
is required.
Please contact Danfoss sales office for further information
Scratc
hes
Level d
ifferen
ces b
etwee
n
dull a
nd s
hining P
EEK
Содержание APP 5.1
Страница 5: ...5 180R9263 IOM APP Pumps v01 01 2013 EU Declaration of Conform ity...
Страница 39: ...3 IOM Electric motors 180R9230 Electric Motors Motor Manual hoyermotors com Manual 180R9230...
Страница 53: ...6 Trouble shooting guide Guideline Trouble shooting guide for APP pumps MAKING MODERN LIVING POSSIBLE...
Страница 69: ...User manual Appendices for IOM APP Pumps APP 5 1 10 2 51 180R9263 IOM APP 5 1 10 2 Appendices v02 01 2013...