AK-PI 200

DE-DB

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products 
already on order provided that such alternations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respecitve companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Ordering

Accessories

Transformer module 230 V / 115 V to 24 V

AK-PS 075

18 VA

Supply 

080Z0053

Type

Function

Application

Language

Code no.

AK-PI 200

Protocol interface

Intermediary link between system manager and controllers 
with DANBUSS data communication 

English, German, 
French, Italian, Dutch, 
Spanish, Portuguese, 
Danish, Swedish and 
Finnish

080Z8521

Data

Supply voltage

24 V a.c.  +/- 20%

Power consumption

AK-PI 200

12 VA

Ambient temperature

During transport

-40 to 70°C

During operation

-20 to 55°C , 
0 to 95% RH (non condensing) 
No shock influences / vibrations

Enclosure

Material

PC / ABS

Density

IP10 , VBG 4

Mounting

For mounting on wall or DIN rail

Weight

Approx.  600 g

Approvals

EU low voltage directive and EMC require-
ments are complied with

LVD tested according to EN 60730
EMC tested
Immunity according to EN 61000-6-2
Emission according to EN 50081-1

UL 873, 

UL file number: E166834

Содержание AK-PI 200

Страница 1: ...REFRIGERATION AND AIR CONDITIONING Protocol interface AK PI 200 Manual ...

Страница 2: ...ware interface Or it can be used on new systems where the majority might be controllers with LON communication and other individual controls can be AKC controllers Principle The link between the system manager and the AK PI 200 is via a TCP IP In this very simple connection the two units can be connected to each other via a crossed cable This is where the IP addresses are set to static addresses O...

Страница 3: ...e network The PI unit is perceived as a controller on the network and its address can be viewed in the IP list Up to two PI units can be connected to the system manager which is master i e has address 1 You set the network address on the front of the system units and on the front of the PI units Set the system manager to address 1 If there are several system managers slave network set these to add...

Страница 4: ...the two units must be a crossed cable A static IP address is always used here b Cables from the units are connected to a router or to a switch A dynamic or static IP address is used here 2 Setting a Router Dynamic There are no settings in the router Static A static address range must be set in the router b AK SM 720 Select static if the connection between the system unit and the AK PI 200 is with ...

Страница 5: ...ion 1 1x it must be set to 1 5 You can activate the Service PIN function at this point If you do this means you do not have to start the scan function in the next point Perform the first scan 1 Start the scan function in the system manager wait for the results the controllers on the LON and MODBUS communication will now be located and visible in the network overview 2 Go to the next page of the ne...

Страница 6: ...networks and addresses that can occur 11 001 is the master system manager 11 002 to 11 010 are slave networks controlled by 11 001 the figure 11 keeps track of the networks and cannot be changed 11 012 to 11 999 are addresses for units on the network The units can be AK PI 200 units or wireless units or they can be controllers in which the data communication takes place via TCP IP 1 xxx will be co...

Страница 7: ... manager that AK PI 200 is connected to The status of the alarm transmission Date and time The quality of the DANBUSS communication signal The configuration display gives access to the following The configuration lock is only used if a static IP address is to be set Under System setup you can give the unit a name IP settings can be entered ...

Страница 8: ...AK PS 075 18 VA Supply 080Z0053 Type Function Application Language Code no AK PI 200 Protocol interface Intermediary link between system manager and controllers with DANBUSS data communication English German French Italian Dutch Spanish Portuguese Danish Swedish and Finnish 080Z8521 Data Supply voltage 24 V a c 20 Power consumption AK PI 200 12 VA Ambient temperature During transport 40 to 70 C Du...

Отзывы: