5-63 Terminal 29 Pulse Output Variable
Option:
Function:
[0] *
No operation
Select the variable for viewing on the terminal 29 display.
This parameter cannot be adjusted while the motor is running.
[45]
Bus ctrl.
[48]
Bus ctrl., timeout
[100]
Output frequency
[101]
Reference
[102]
Feedback
[103]
Motor current
[104]
Torque rel to limit
[105]
Torq relate to rated
[106]
Power
[107]
Speed
[108]
Torque
[109]
Max Out Freq
[113]
Ext. Closed Loop 1
[114]
Ext. Closed Loop 2
[115]
Ext. Closed Loop 3
5-65 Pulse Output Max Freq #29
Range:
Function:
5000 Hz*
[0 - 32000 Hz]
Set the maximum frequency for terminal 29 corresponding to the output variable set in par.
5-63
Terminal 29 Pulse Output Variable
.
This parameter cannot be adjusted while the motor is running.
5-66 Terminal X30/6 Pulse Output Variable
Option:
Function:
[0] *
No operation
Select the variable for read-out on terminal X30/6.
This parameter cannot be adjusted while the motor is running.
This parameter is active when option module MCB 101 is installed in the frequency converter.
[45]
Bus ctrl.
[48]
Bus ctrl., timeout
[100]
Output frequency
[101]
Reference
[102]
Feedback
[103]
Motor current
[104]
Torque rel to limit
[105]
Torq relate to rated
[106]
Power
[107]
Speed
[108]
Torque
[109]
Max Out Freq
[113]
Ext. Closed Loop 1
[114]
Ext. Closed Loop 2
[115]
Ext. Closed Loop 3
3 Parameter Description
ADAP-KOOL
®
Drive Programming Guide
82
MG.11.N1.02 - VLT
®
is a registered Danfoss trademark
3