FDC Control
P109024
Left coil orientation
Right coil orientation
C129
H030
*QC120
C124
C123
G020
QC135
QC130
QC125
C300
C107
C122
C125
C128B
C128A
C128
*C200
C120
C128C
* Included in overhaul seal kit
Shaft
Inspect the shaft for any signs of damage. Replace the shaft if a groove exists at the sealing land surface
that may let dirt into or hydraulic fluid out of the unit. If necessary, clean the sealing area with a non-
abrasive material. Inspect the input splines or keyway, block spines and output splines. Replace the shaft
if damaged. Ensure that the shaft’s splines are straight and lubricate the shaft with a light coating of
hydraulic fluid.
Inspect shaft
J010
i
P101 360
l
Journal Bearing
Inspect the journal bearings for damage or excessive wear. Replace journal bearings if scratched, warped,
or excessively worn. The polymer wear layer must be smooth and intact.
Inspect journal bearings
B030
P101 363
Repair Instructions
Series 45 Frame K2 Axial Piston Pumps
Inspection
©
Danfoss | April 2017
AX00000305en-US0101 | 23