10. Remove plug (C153). Remove the cartridge valve nut (C125), electric solenoid (C155), and cartridge
valve (C150) from the electric control manifold.
Disassemble electric control
P108 668E
G020
G030
C200
C102
C103
C132
C112
C104
C300
C125
C155
C150
C149
C154
C152
C151
C113
C115
C133
C135
C114
C118
C134
C138A
C138
C153
Electronic Torque Limiting Control
Repair
Disassembly, inspection and reassembly steps are the same as the steps in the previous topic (Electric
Controls). This includes repair of the spools and plugs.
The solenoid (C155), nut (QC125), and O-rings (QC120) for the valve are available as separate repair
parts. The valve is only available as a complete assembly (QC150).
If it is necessary to remove the orifice (H020), use a 3 mm internal hex wrench. Torque it to 2.7 Nm [24
in-lb] when it is installed in the manifold.
Repair Instructions
Series 45 Frame K2 Axial Piston Pumps
Disassembly
©
Danfoss | April 2017
AX00000305en-US0101 | 15