background image

4

3060

Installation

Installation

1.  Remove lower setting dial. Set all four tappets to top 

of upper dial. Unscrew 4BA screw and remove outer 

case.

2.  Slacken two screws securing plug-in module to 

backplate and separate module from backplate by 

pulling upwards.

3.  Fix backplate to wall (3 hole fixing).

4.  Referring to wiring diagrams below and opposite 

make electrical connections as shown (as applicable). 

The diagrams indicate that terminals 3 and 5 are not 

internally connected to the programmer and may 

therefore be used as spare wiring terminals if required.

5.  Ease of installation can be achieved by the use of the 

Danfoss Randall Wiring Centre which is obtainable 

from most Builders Merchants and Distributors.

 

NOTE: If a Wiring Centre is used follow the 

installation instructions included with that unit and 

not the following wiring diagrams.

6.  Secure cable cores under cable clamp.

Содержание 3060

Страница 1: ...nstructions electro mechanical programmer for controlling heating hot water This product complies with the following EC Directives Electro Magnetic Compatibility Directive EMC 2004 108 EC Low Voltage...

Страница 2: ...2 INDEX Index Installation Product specification 3 Installation 4 Wiring 4 5 User Your programmer 6 Programming the unit 6 7 Setting the clock 7 Using the programmer 8 9 Contact details 12...

Страница 3: ...supply 230 15 Vac 50 60Hz Switch action 2 x SPST type 1B Switch rating Max 264 Vac 50 60Hz 3 1 A Timing accuracy 1 min month Enclosure rating IP30 Max ambient temperature 55 C Dimensions mm W H D 102...

Страница 4: ...posite make electrical connections as shown as applicable The diagrams indicate that terminals 3 and 5 are not internally connected to the programmer and may therefore be used as spare wiring terminal...

Страница 5: ...h fully motorised zone valves requiring both ON and OFF electrical signals when used in the heating circuit 1 2 3 4 5 6 7 8 9 10 S L L N Brown Orange Grey Blue Danfoss Randall HP22 or HP28 SRZV Hot Wa...

Страница 6: ...tly ON constantly OFF each in different combinations During the summer the central heating can be turned off whilst still controlling the hot water at the set times Your Programmer Programming the uni...

Страница 7: ...NB Clock is in 24 hour mode If you want your heating and hot water ON between 7am and 10am and ON again between 5pm and 11pm set tappets as follows A at 1st ON time 7 B at 1st OFF time 10 C at 2nd ON...

Страница 8: ...Heating and Hot Water will remain OFF until you change the setting 2 H TWICE W TWICE In this position the Heating and Hot Water will both come on and go off according to the times you have programmed...

Страница 9: ...A and stay on until D 6 H OFF W TWICE In this position the Heating will be permanently OFF and the Hot Water will come on and go off according to the times you have programmed ON at A OFF at B ON at C...

Страница 10: ...10...

Страница 11: ...11...

Страница 12: ...Name Tel Visit our website www heating danfoss co uk Email our technical department ukheating technical danfoss com Call our technical department 0845 121 7505 8 45 5 00 Mon Thurs 8 45 4 30 Fri For a...

Отзывы: