evolution
Ver
.13
DIGITAL CONTROLLER AND INDICATOR FOR
HEATING OR COOLING WITH NATURAL
DEFROST THROUGH COMPRESSOR SHUTDOWN
MT-512
e
2HP
Control functions
shutdown
Functions
lockdown
Serial
programming
Protection
level
Manual
defrost
IP 65
FRONT
Image I: MT-512E 2HP - 115Vac
1. DESCRIPTION
2. SAFETY RECOMMENDATIONS
3.
4. TECHNICAL SPECIFICATIONS
Periodical defrost may be performed with
MT-512
e
2HP
by stopping the compressor (natural
defrost) and forcing defrost manually. It is provided with a powerful 16A relay for actuating loads of up to
2HP, in addition to a command output combined with a timer for programming refrigeration and
defrosting times. Another feature available is the turning off of the control functions, making the
MT-512
e
2HP
operate only as a temperature indicator. It is also provided with a configurable
digital filter, which has the purpose of simulating mass increase in the environment sensor, thus
increasing its response time, i.e., it renders the sensor response slower (delay). Through an intelligent
function blocking system, it prevents unauthorized personnel from changing the control parameters.
MT-512
e
2HP
can also be set for heating.
Product conforming to UL Inc. (United States and Canada) and NSF
.
(United States)
- Check the controller for correct fastening;
- Make sure that the power supply is off and that it is not turned on during the controller installation;
- Read the present manual before installing and using the controller;
- Use adequate
(PPE);
- For application at sites subject to water spills, such as refrigerated counters, install the protecting vinyl
supplied with the controller;
- For protection under more critical conditions, we recommend the Ecase cover, which we make
available as an optional item (sold separately);
- The installation procedures should be performed by a qualified technician.
• Cold storages
•
• Industrial heating / Cooling equipment
• Any other type of equipment requiring precise temperature control
Personal Protective Equipmenet
Reach-In Coolers / Stand Up Coolers
APPLICATIONS
Control temperature
(**)
Resolution
5. INDICATIONS AND KEYS
Upper Key
MT-512
e
2HP
Lower Key
Set Key
Menu Key (Flatec)
User-friendly
Cooling indication LED
Heating indication LED
Defrost indication LED
Temperature unit indication LED
Control functions OFF indication LED
Functions lockdown indication LED
- 50 to 105°C (-58 to 221°F)
0.1°C (-10 to 100°C) and 1°C at the rest of the range
115 Vac
Image III: MT-512EL 2HP - 12Vac/dc
Power supply
MT-512E 2HP:
115 or 230 Vac
* (50/60 Hz)
±10%
MT-512EL 2HP:
12 or 24 Vdc or Vac
*
+10%
Maximum load current
(***)
16 A for resistive-type loads and 12 A for inductive-type
loads
Maximum load power
(***)
2HP
Operating temperature
0 to 50°C / 32 to 122°F
Operating humidity
10 to 90% RH (without condensation)
(*) Admissible variation in relation to the voltage rating.
(**) This instrument measures and controls temperatures of up to
, using the silicone sensor cable SB59
(sold separately).
(***) For higher loads, use contactor.
200°C/392°F
Protection level
Dimensions (mm)
Cutout dimensions (mm)
IP 65 (frontal)
76 x 34 x 77 mm (Width x Height x Depth)
X = 71±0,5 Y = 29±0,5 (see image V)
6. WIRING DIAGRAM
6.1. Identifications (see Images I to IV)
- Image I:
MT-512E 2HP, supplied at 115 Vac.
- Image II:
MT-512E 2HP, supplied at 230 Vac.
- Image III:
MT-512EL 2HP, supplied at 12 Vac/dc.
- Image IV:
MT-512EL 2HP, supplied at 24 Vac/dc.
Image II: MT-512E 2HP - 230 Vac
230 Vac
POWER
12Vac/dc
Image IV: MT-512EL 2HP - 24Vac/dc
POWER
24Vac/dc
6.2. Temperature sensor connection
- Connect the sensor wires to terminals ‘1 and 2’: the polarity is not relevant.
- Length of the sensor cables can be increased by user himself to up to 200 meters, using a PP 2x24
AWG cable.
- For immersion in water, use a thermowell (Image VI - item 12), available in the Full Gauge Controls
product line (sold separately).
S u r g e P r o t e c t i v e
Device (SPD)
(sold separately)
W i r i n g d i a g r a m f o r
instalation of SPD in
magnectic contactor
A1 and A2 are the terminals of
the contactor coil.
SPD
A1
A2
W i r i n g d i a g r a m f o r
instalation of SPD in line
with loads
For direct drive take in to
consideration the specified
maximum current.
LOAD
IMPORTANT
SCREWDRIVER SLOT 3/32''(2.4mm) FOR ADJUSTMENTS IN THE SIGNAL TERMINALS;
SCREWDRIVER PHILLIPS #1 FOR ADJUSTMENTS IN THE POWER TERMINALS;
THE USE OF APPROPRIATE TOOLS IS ESSENTIAL TO AVOID DAMAGE IN THE CONNECTION AT INSTRUMENT
TERMINALS:
CONTROLLER
WIRING
TERMINALS
TEMPERATURE
SENSOR
WIRING
TERMINALS
LOAD
CONTROLLER
WIRING
TERMINALS
WIRING
TERMINALS
TEMPERATURE
SENSOR
LOAD
CONTROLLER
WIRING
TERMINALS
WIRING
TERMINALS
TEMPERATURE
SENSOR
LOAD
CONTROLLER
WIRING
TERMINALS
WIRING
TERMINALS
TEMPERATURE
SENSOR
LOAD
SPD
MT512E2HP13-02T
-15381
POWER
GRID
}
POWER
GRID
}
POWER
GRID
}
POWER
GRID
}
E251415
COMPONENT
Have this manual in the palm of
your hand by
FG Finder
application.