background image

Creating Cable Openings

The gland plate is a sheet of metal with studs along the outer
edge. The gland plate provides cable entry and cable
termination points, and must be installed to maintain the
IP21/IP54 (Type 1/Type 12) protection rating. The gland plate
is placed between the drive enclosure and the pedestal.
Depending on stud orientation, the plate can be installed from
inside the enclosure or by taking off the front cover of the
pedestal. To prepare and install the gland plate, use the
following steps. Refer to 

Illustration 1.6

.

1.

Create cable entry holes in the gland plate using a
sheet metal punch.

2.

If installing the gland plate through the pedestal,
remove 6 M5x14 countersunk screws securing the
pedestal front plate.

3.

Insert the gland plate using 1 of the following
methods:

3a

To insert the gland plate through the
pedestal, slide the gland plate through the
slot in the front of the pedestal.

3b

To insert the gland plate through the
enclosure, angle the gland plate until it
slides under the slotted brackets.

4.

Align the studs on the gland plate to the holes in the
pedestal and secure with 10 M5 nuts.

5.

Torque each nut to 2.3 Nm (20 in-lb).

6.

If removed previously, reposition the pedestal front
plate and fasten it with 6 M5x14 countersunk screws.

1

Gland plate

4

Slot in pedestal

2

Cable entry hole

5

Front cover

3

M5 nut

6

M5 countersunk screw

Illustration 1.6 Installing the Gland Plate

Installation Instructions

Tall Pedestal Kit for E1h/E2h Drives
VLT

®

 FC Series FC 102, FC 103, FC 202, and FC 302

MI35V102

Danfoss A/S © 03/2018 All rights reserved.

5

Содержание 176F6764

Страница 1: ...n and installing or servicing with power connected can cause death serious injury or equipment failure To avoid death serious injury or equipment failure Only use qualified electricians for the instal...

Страница 2: ...15 7 in and features a front grill to allow the airflow necessary to cool the drive components The gland plate ships with the drive and is necessary to maintain the IP21 Type 1 or IP54 Type 12 protect...

Страница 3: ...ating conditions and cable access 2 Access the mounting holes by removing the front panel of the pedestal 3 Set the pedestal on the floor and secure using 6 bolts through the mounting holes Refer to t...

Страница 4: ...lustration 1 7 and Illustration 1 9 1 Enclosure 4 M10 nylon insert lock nut 2 Pedestal 5 Locking bracket 3 Bolt at rear of pedestal 6 Slotted hole in enclosure Illustration 1 4 Pedestal to Enclosure B...

Страница 5: ...rsunk screws securing the pedestal front plate 3 Insert the gland plate using 1 of the following methods 3a To insert the gland plate through the pedestal slide the gland plate through the slot in the...

Страница 6: ...of E1h Drive with Tall Pedestal Illustration 1 8 Side View of E1h Drive with Tall Pedestal Installation Instructions Tall Pedestal Kit for E1h E2h Drives VLT FC Series FC 102 FC 103 FC 202 and FC 302...

Страница 7: ...of E2h Drive with Tall Pedestal Illustration 1 10 Side View of E2h Drive with Tall Pedestal Installation Instructions Tall Pedestal Kit for E1h E2h Drives VLT FC Series FC 102 FC 103 FC 202 and FC 302...

Страница 8: ...ucts already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the resp...

Отзывы: