Operator's Manual for the DM100 S-VDR
Copyright Danelec Marine A/S
500
ANALOG module 2
Missing (AN16-31)
If only one module is affected:
A module has been removed or has failed. Check that the
module is installed correctly.
If installed in a modular SIU, the blue “link” LED for the
module must be illuminated. If the LED is already illuminated
switch the power to the SIU off and on. If the error persists
replace the module.
If all modules in the SIU are affected:
Check the power to the SIU.
Check the cable from the SIU to the DAU and link status; see
section 4.1.7,
Error! Reference source not found.
and
Error!
Reference source not found.
.
If no error is found, try to restart both the DAU and the SIU
(power off and then on)
If the error persists, the DPU or the Module rack/Uni rack is
probably defective.
501
DIGITAL module 5
Missing (DI64-79)
502
DIGITAL module 6
Missing (DI80-95)
503
DIGITAL module 7
Missing (DI96-111)
504
DIGITAL module 8
Missing (DI112-127)
505
SERIAL module 3
Missing (SI16-23)
506
SERIAL module 4
Missing (SI24-31)
DBS10912-10