background image

OM-CP-RFCURRENT2000A

Wireless Current Data Logger 

Содержание OM-CP-RFCURRENT2000A

Страница 1: ...OM CP RFCURRENT2000A Wireless Current Data Logger...

Страница 2: ...alone data logger or used with the OM CP RFC1000 EXT wireless transceiver to transmit data back to a central PC The OM CP RFCURRENT2000A transmits up to 500 line of sight to the OM CP RFC1000 EXT tran...

Страница 3: ...data logger by clicking the Start icon 7 To download data select the device in the list click the Stop icon and then click the Download icon A graph will automatically display the data 1 Install the...

Страница 4: ...fications will not be received if settings are incorrect 5 Click OK The OK button will be disabled if the Rule name box is empty Changing the Alarm Settings of a Device 1 In the Connected devices pane...

Страница 5: ...on then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the available communication interfaces If the OM CP RFC1000 EXT is listed here then th...

Страница 6: ...4 Push the cover closed until it clicks Recalibration Standard recalibration for the OM CP RFCURRENT2000A 3A are two points 0A and 1 00A For the OM CP RFCURRENT2000A 20mA the standard calibration poin...

Страница 7: ...ature CO2 flow rate and more Calibration Digital calibration through software Calibration Date Automatically recorded within device Battery Type Ultralife 9V lithium battery included user replaceable...

Страница 8: ...line of sight unobstructed 500 max indoors typical urban environment Measurement Wireless Battery Warning WARNING MAY LEAK FLAME OR EXPLODE IF DISASSEMBLED SHORTED CHARGED CONNECTED TOGETHER MIXED WI...

Страница 9: ...Quick Start Manual OM CP RFC1000 EXT Wireless Transceiver Other models available OM CP RFC1000 EUR Approved for European markets OM CP RFC1000 IP69K Splash Proof for harsh environments...

Страница 10: ...85 C and a humidity range of 0 to 95 RH non condensing The OM CP RFC1000 EXT is rated IP40 and is protected against solids that are greater than 1mm in size This device is not water resistant LEDs Th...

Страница 11: ...performance both the OM CP RFC1000 EXT and the Omega data loggers should be mounted in the same orientation This usually means that the external antenna should be pointing straight up The antenna can...

Страница 12: ...r The images below show the orientations available of the switches for each channel Channel 26 all switches in the up position is not supported Follow the instructions below to configure the channel s...

Страница 13: ...o wireless mode by holding down the Wireless button for 5 seconds Deploying and Activating Devices 1 Plug the OM CP RFC1000 EXT into the USB port on the base station computer Additional OM CP RFC1000...

Страница 14: ...OM CP RFC1000 EXT is not properly connected 1 In the software click the File button then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the a...

Страница 15: ...als FCC ID OA3MRF24J40MC IC 7693A 24J40MC Transmission Distance To other OM CP RFC1000 EXTs 4000 max outdoor line of sight unobstructed 1000 max indoors typical urban environment Transmission Distance...

Страница 16: ...ustrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appa...

Страница 17: ...l application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA...