manualshive.com logo in svg
background image

Quick Start Manual

Quick Start Steps

 

1.

 

Install the Omega Software and USB Drivers onto a Windows PC. 

2.

  

The OM-CP-RFC1000-EXT interface device comes with a USB cable. Plug one end of the cable into 
an available USB port on the PC and plug the opposite end of the cable into the communication 
port on the OM-CP-RFC1000-EXT.

3.

  

Push and hold the wireless button on the OM-CP-RFCURRENT2000A for 5 seconds to activate wireless 
communication. The display will confirm “Wireless: ON” and the blue LED will blink every 15 seconds.

4.  

Launch the Omega Software. All active Omega data loggers that are within range will automatically  
appear in the connected devices window. Each data logger in the list can be identified by serial 
number (printed on the exterior of the logger).

5. 

To claim a device, select the desired data logger in the list and click the Claim icon.

6.  

Select the start method, reading rate and any other parameters appropriate for the desired data  
logging application. Once configured, deploy the data logger by clicking the 

Start

 icon.

7.  

To download data, select the device in the list, click the 

Stop

 icon, and then click the 

Download

 

icon. A graph will automatically display the data.

1.

  

Install the Omega Software and USB Drivers onto a Windows PC. 

2.

  

Before plugging the data logger in the computer, make sure the wireless setting on the device is set to 
“Wireless: OFF”. If wireless mode is on, press and hold the wireless button on the device for 5 seconds. 

3.

  

The OM-CP-RFCURRENT2000A comes with a USB cable. Plug one end of the cable into an available  
USB port on the PC and plug the opposite end of the cable into the communication port on the  
OM-CP-RFCURRENT2000A.

4.

  

Launch the Omega Software. The OM-CP-RFCURRENT2000A will appear in the connected devices  
window indicating the device has been recognized.

5.

  

Select the start method, reading rate and any other parameters appropriate for the desired data logging 
application. Once configured, deploy the data logger by clicking the 

Start

 icon.

6.

  

To download data, select the device in the list, click the 

Stop

 icon, and then click the 

Download

 icon.  

A graph will automatically display the data.

Product Operation (Plugged In)

Product Operation (Wireless)

Содержание OM-CP-RFCURRENT2000A

Страница 1: ...OM CP RFCURRENT2000A Wireless Current Data Logger...

Страница 2: ...alone data logger or used with the OM CP RFC1000 EXT wireless transceiver to transmit data back to a central PC The OM CP RFCURRENT2000A transmits up to 500 line of sight to the OM CP RFC1000 EXT tran...

Страница 3: ...data logger by clicking the Start icon 7 To download data select the device in the list click the Stop icon and then click the Download icon A graph will automatically display the data 1 Install the...

Страница 4: ...fications will not be received if settings are incorrect 5 Click OK The OK button will be disabled if the Rule name box is empty Changing the Alarm Settings of a Device 1 In the Connected devices pane...

Страница 5: ...on then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the available communication interfaces If the OM CP RFC1000 EXT is listed here then th...

Страница 6: ...4 Push the cover closed until it clicks Recalibration Standard recalibration for the OM CP RFCURRENT2000A 3A are two points 0A and 1 00A For the OM CP RFCURRENT2000A 20mA the standard calibration poin...

Страница 7: ...ature CO2 flow rate and more Calibration Digital calibration through software Calibration Date Automatically recorded within device Battery Type Ultralife 9V lithium battery included user replaceable...

Страница 8: ...line of sight unobstructed 500 max indoors typical urban environment Measurement Wireless Battery Warning WARNING MAY LEAK FLAME OR EXPLODE IF DISASSEMBLED SHORTED CHARGED CONNECTED TOGETHER MIXED WI...

Страница 9: ...Quick Start Manual OM CP RFC1000 EXT Wireless Transceiver Other models available OM CP RFC1000 EUR Approved for European markets OM CP RFC1000 IP69K Splash Proof for harsh environments...

Страница 10: ...85 C and a humidity range of 0 to 95 RH non condensing The OM CP RFC1000 EXT is rated IP40 and is protected against solids that are greater than 1mm in size This device is not water resistant LEDs Th...

Страница 11: ...performance both the OM CP RFC1000 EXT and the Omega data loggers should be mounted in the same orientation This usually means that the external antenna should be pointing straight up The antenna can...

Страница 12: ...r The images below show the orientations available of the switches for each channel Channel 26 all switches in the up position is not supported Follow the instructions below to configure the channel s...

Страница 13: ...o wireless mode by holding down the Wireless button for 5 seconds Deploying and Activating Devices 1 Plug the OM CP RFC1000 EXT into the USB port on the base station computer Additional OM CP RFC1000...

Страница 14: ...OM CP RFC1000 EXT is not properly connected 1 In the software click the File button then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the a...

Страница 15: ...als FCC ID OA3MRF24J40MC IC 7693A 24J40MC Transmission Distance To other OM CP RFC1000 EXTs 4000 max outdoor line of sight unobstructed 1000 max indoors typical urban environment Transmission Distance...

Страница 16: ...ustrie Canada applicables aux appareils radio exempts de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appa...

Страница 17: ...l application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA...

Отзывы: