Operator's Manual for the DM100 S-VDR
Copyright Danelec Marine A/S
7.2 Additional error codes for installations utilizing a SIU and 2
nd
RVI
400-
423
SERIAL
Timeout on SIxx
Mandatory serial data is not received. Check that the source is
on. Check the signal from the source (serial monitor in VDR
explorer, WEB status or VGA status display). If no signal is
present, check the cable and make sure that the configuration is
correct.
441
SERIAL module 2
Missing (SI08-12)
The serial data interface module on the SAP board in the DPU
cannot be detected. If the error persists, the DPU is probably
defective.
442
ANALOG module 1
Missing (AN00-15)
If only one module is affected:
A module has been removed or has failed. Check that the
module is installed correctly.
If installed in a modular SIU the blue “link” LED for the
module must be illuminated. If the LED is already illuminated
switch the power to the SIU off and on. If the error persists
replace the module.
If all modules in a SIU are affected:
Check the power to the SIU.
Check the cable from the SIU to the DAU and link status; see
section 4.1.7,
Error! Reference source not found.
and
Error!
Reference source not found.
.
If no error is found, try to restart both the DAU and the SIU
(power off and then on)
If the error persists, the DPU or the Module rack/Uni rack is
probably defective.
443
DIGITAL module 1
Missing (DI00-15)
444
DIGITAL module 2
Missing (DI16-31)
445
DIGITAL module 3
Missing (DI32-47)
446
DIGITAL module 4
Missing (DI48-63)
450-
452
SIU xxxxxxx
Module in wrong slot
xxxxxxx = SERIAL, ANALOG, DIGITAL
A module has been misplaced. Modules must be installed
according to the VDR configuration.
460-
462
SIU xxxxxxx
Wrong MR address
xxxxxxx = SERIAL, ANALOG, DIGITAL
A SIU with the wrong Module Rack address has been detected.
Set the MR/UR address to 0 or 1. See section
Error!
Reference source not found.
470-
472
SIU xxxxxx
Module duplicate
xxxxxxx = SERIAL, ANALOG, DIGITAL
The VDR has detected two different modules with the same
MR/UR address and slot number. This may occur if two SIUs
are connected to the DAU, with the same address.
482
RVI VIDEO
Module missing
VIDEO module 2 cannot be detected. The most probable cause
is that that the cable to the RVI from the DPU is disconnected
or the RVI is defective. In addition, for an AC powered RVI:
Power to the RVI is switched off, the internal Ethernet cable in
the RVI is disconnected, or the video interface module is
defective.
484
RVI VIDEO
Wrong RVI address
An AC powered RVI with incorrect RVI address has been
detected. The RVI address must be 0 or 1. All RVIs connected
to the VDR must be setup in the VDR configuration.
DBS10912-10
Page 23/36