Mechanical Installation
The PDU-16SS may be mounted anywhere inside the vehicle away from heat, moisture or the elements.
NOTE the PDU is not weather tight. Do not mount it in the engine compartment, on the exterior of the vehi-
cle or an area where moisture, dirt or other contaminants can fall into the exposed areas of the PDU. Ensure
that the mounting location is flat and the device is secured to solid vehicle body parts.
1.
Determine an appropriate mounting location.
2.
Confirm there is adequate access and clearance for the wiring and all connections.
3.
Secure the PDU with 4 self-tapping mounting screws.
Electrical Installation
12V Battery
Using appropriate size wire connect to the positive battery terminal fuse at the battery side with 100A fuse or
a circuit breaker.
Ground
Using appropriate size wire connect to the negative battery terminal or a suitable chassis ground.
Ignition Sense
Connect this terminal to the vehicle ignition switch using 18 gauge wire.
Battery Sense
Connect this terminal directly to the positive of the battery using a 18 gauge wire fused with a 5A fuse.
This connection must be made in order for the PDU-16SS to work.
Ground Sense
Connect this terminal to the negative side of the battery or a suitable chassis ground.
This connection must be made in order for the PDU 16SS to work.
Outputs
The PDU offers the following outputs. (1) 30A in group 1, (6) 15A in group 1, (7) 15A in group 2 and (2) direct-
ly from the battery (this output is available even when the PDU is dormant).
NOTE: When the IGNITION is OFF and the main +12V power input is disconnected, the DISPLAY will
stay ON until both timers expire or the BATTERY SENSE input is disconnected.