212-0024-SS 

July 30th, 2019

 

Introduction 

The PDU-16SS is designed to provide automotive emergency and public service vehicle equipment installers 
with a solid state, single point power distribution system for installed electrical devices.  The installation is 
fast, reliable and safe.  It offers programmable low battery voltage shutdown, programmable timed shut-
down, power distribution and equipment protection.  The PDU-16SS provides a direct, easily traceable route 
to the input power source avoiding interfering with the vehicles factory wiring harnesses.  All circuits are in-
dividually fused (MAXI fuse for the heavy duty outputs & MINI fuses for the standard outputs) and each out-
put has a FUSE OK LED indicator for ease of troubleshooting. 

 

Features 

 

Programmable Low Battery Voltage Shutdown 

 

Programmable Timed Shutdown 

 

Vehicle Battery Voltage Monitoring 

 

Each output has an LED fuse status indicator 

 

Standby Mode 

 

Timed Shutdown Mode 

 

Test Mode 

 

Reset Mode 

 

16 Outputs 

 

 

Technical Specifications 

Voltage Range: 11-18 VDC 
Maximum Current Load:  15A per output, fused at 20A 
  

 

 

 

 

 30A per heavy duty output, fused at 50A 

  

 

 

 

 

 100A total maximum current per PDU 

Stand-by Current:  0A 
Programmable Low Voltage Disconnect:  Programmable from 11VDC 
 

 

 

 

Factory default set at 11.5VDC (10 second delay) 

 

NOTE: 

Battery manufacturers recommend to not program low voltage disconnect below 11 VDC   

 

unless the vehicle is equipped with a second battery.

 

 

 
High Voltage disconnect set at 18VDC, (10 second delay) 
Programmable timer setup: 1 minute - 99.59 hours. 
Fuse Type:  MINI fuse for regular outputs. 
 

 

 MAXI fuse for heavy-duty outputs. 

Operating Temperature:  -40

° C to +65° C (-40F to +149F) 

Dimensions:  L 10.55” X W 4.26” X H 1.1” 
Weight:  1.85 Lbs  

Содержание PDU-16SS

Страница 1: ...SS Table of Contents Product Overview 2 Introduction Features Technical Specifications 3 Warnings 4 Installation 5 Wiring Diagram 6 Wire Gauge Size Tables 7 Modes of Operation 8 Programming Low Voltage Shutdown and Timed Shutdown 9 Package Contents 10 Warranty and Product Return Policy 12 ...

Страница 2: ...212 0024 SS 2 July 30th 2019 Product Overview Figure 1 PDU 16SS ...

Страница 3: ...Features Programmable Low Battery Voltage Shutdown Programmable Timed Shutdown Vehicle Battery Voltage Monitoring Each output has an LED fuse status indicator Standby Mode Timed Shutdown Mode Test Mode Reset Mode 16 Outputs Technical Specifications Voltage Range 11 18 VDC Maximum Current Load 15A per output fused at 20A 30A per heavy duty output fused at 50A 100A total maximum current per PDU Stan...

Страница 4: ...hould be properly trained in the operation of this device to ensure both operator and public safety 9 Any device used inside a vehicle may cause severe personal injury if not properly mounted and secured Objects used in the vehicle may become airborne during a collision or other sudden chang es in vehicle speed or direction such as braking acceleration or turns 10 Be sure to mount unit through the...

Страница 5: ...t the battery side with 100A fuse or a circuit breaker Ground Using appropriate size wire connect to the negative battery terminal or a suitable chassis ground Ignition Sense Connect this terminal to the vehicle ignition switch using 18 gauge wire Battery Sense Connect this terminal directly to the positive of the battery using a 18 gauge wire fused with a 5A fuse This connection must be made in o...

Страница 6: ...212 0024 SS 6 July 30th 2019 Figure 2 Wiring NOTE The BATTERY SENSE lines MUST be connected As shown in Figure 2 in order for the unit to work Wiring Diagram ...

Страница 7: ...ngth 3 drop 5 ft 5 10 ft 10 15 ft 15 20 ft 25 30 ft 25 10 6 6 4 2 50 6 4 2 2 0 75 6 2 1 0 3 0 100 4 2 0 2 0 4 0 Table 2 Recommended Circuit Load Wire Size Max Total Load Current Amps Wire Size AWG vs Wire Length 3 drop 1 5 ft 5 10 ft 10 15 ft 15 20 ft 25 30 ft 5 18 18 18 16 14 10 18 16 14 14 12 15 18 14 12 12 10 20 16 14 12 10 8 ...

Страница 8: ...voltage reaches a pre set value This setting is the same for both groups Timed Shutdown Mode The PDU allows the user to set the time remaining after the ignition switch is turned off This setting is the same for both groups The 7 segment display will cycle through and indicate the time remaining for each output group Test Mode Pressing the TIME SETUP TEST button for at least 2 seconds will start a...

Страница 9: ...he vehicle battery voltage drops below the Low Voltage Shutdown values for GROUP 1 or GROUP 2 outputs the outputs for that group will be OFF unconditionally The minimum shutdown voltage cannot be set below 11 5VDC unless the vehicle is being fitted with a second battery Timed Shutdown Setup The PDU 16SS factory default shutdown times are set to 2 minutes for GROUP 1 outputs 2 hours for GROUP 2 out...

Страница 10: ...6SS unit w 16 out display dual programmable timer 1 212 0024 SS Manual PDU 16SS unit 1 Designator sheet for PDU 16SS to record all setup installa 4 196 0070 Lug LD 6 AWG stud 1 4 16 205 0052 Spade 8 16 14 Ga Package Contents NOTE MINI and MAXI fuses are available for purchase ...

Страница 11: ...212 0024 SS 11 July 30th 2019 NOTES ...

Страница 12: ...or removal or installation Lamps flash tubes batteries or other items considered consumables are not covered under warranty This warranty is in lieu of all other express warranties D R Electronics makes no warranties ex pressed or implied other than the express warranties contained herein WARRANTY PRODUCT RETURN POLICY In order to provide you with faster service product returns for repair or repla...

Отзывы: