60
Fahrzeug-/Funktionsdecoder
ab Firmware-Version 1.11
60
Locomotive/Vehicle function decoder
from firmware version 3.12
CV
Name and definition
Range
Standard
01
Address
(not relevant to PD*)
Addresses higher than 127 are only usable in MM-operation
1-255
3
02
Starting voltage
0-15
0
03
Acceleration time
The value corresponds to the time in seconds from start to maximum speed
0-255
3
04
Deceleration time
The value corresponds to the time in seconds from the maximum speed to stop
0-255
3
05
Maximum speed
(see supplement 2)
0-127
92
07
Version number
(read only)
08
Manufacturer identification
(read only)
97 = Doehler & Haass (Decoder reset with “8“)
09
Motor frequency
(not relevant to FH*)
Bit
Function Value
0........0 = 32 kHz, 1 = 16 kHz ..........................................................................1
1........0 = 16/32 kHz, 1 = low frequency .........................................................2
2........proportional part limitation ....................................................................4
3........Switch off short circuit protection .........................................................8
0-15
1
8.2.1 List of supported CV
The abbreviation
FH
* refers to the decoder types
FH05B, FH16A, FH18A
and
FH22A
.
The abbreviation
PD*
refers to decoder types
PD05A, PD06A, PD12A, PD18A
and
PD21A
.
Содержание FH16A