65
Fahrzeug-/Funktionsdecoder
ab Firmware-Version 1.11
65
Locomotive/Vehicle function decoder
from firmware version 3.12
CV
Name and definition
Range
Standard
52
Dimming LV/LR
0 = dark … 31 = full brightness
0-31
31
53
Dimming low beam light
(see CV156)
0 = dark … 31 = full brightness
0-31
15
54
Dimming AUX1
0 = dark … 31 = full brightness
0-31
31
55
Dimming AUX2
0 = dark … 31 = full brightness
0-31
31
56
Motor control proportional
(not relevant to FH*)
Only if CV50 = 0, see: www.doehler-haass.de/„Häufige Fragen“ (only in German)
0-7
3
57
Motor control integral
(as CV56)
0-3
3
58
Motor control measurement period
(as CV56)
0-3
1
59
Motor control impulse width
(as CV56)
0-7
3
60
Brake sections
1 or 2
0, 1
0
61
Shuntig gear speed
(as CV05)
0-127
63
62
Shunting gear deceleration
(as CV03)
0-255
1
63
Starting delay speed step 1
(see CV124)
Each 100 ms, 0 = deacitvated
0-250
0
64
Function mapping F2 (r)
(see supplement 1)
In case CV64 should have a different value than CV36,
you must set CV36 first and then CV64
0-255
8