NL4 connection with cover plate
The two NL4 connector sockets of the cabinet's connector panel
are located in a recess to allow the use of the cover plate
[1]
together with NL4 cable connectors, as shown in the graphic
opposite.
Note: Neutrik NL4FC type connectors must be used for this
option.
The cover plate is equipped with two knockout openings to allow
daisy chaining of the loudspeaker.
To use the NL4 connection, proceed in the same manner as
described in the previous section.
2.3. Operation
NOTICE!
Only operate d&b loudspeakers with a correctly configured d&b
amplifier, otherwise there is a risk of damaging the loudspeaker
components.
Application
Setup
Cabinets per
channel
Vi7P
V7P
2
Vi10P
V10P
2
For applicable d&b amplifiers, the controller setups are available
in Dual Channel and/or Mix TOP/SUB mode. For combinations
with active subwoofers fed by a single 4-wire cable Mix TOP/SUB
mode must be selected.
2.3.1. Controller settings
For acoustic adjustment the functions CUT, HFA and CPL can be
selected.
CUT circuit
Set to CUT, the cabinet low frequency level is reduced. The
cabinets are now configured for use with actively driven d&b
subwoofers.