background image

 

2.3.1. Controller settings

For acoustic adjustment the 100 Hz function can be selected.

100 Hz circuit
If the 100 Hz circuit is selected, the upper operating frequency of

the system is reduced from 115 Hz to 95 Hz.

It can be used when actively driven Vi-GSUBs are used to

supplement V-Point cabinets operated in full range mode. The

100 Hz mode can also be used to compensate for the effect of

close coupling between the Vi-GSUB and V-Point cabinets

operated in CUT mode.

2.4. Technical specifications

Vi-GSUB system data

Frequency response (–5 dB standard)

37 Hz - 115 Hz

Frequency response (–5 dB 100 Hz mode)

37 Hz - 95 Hz

Max. sound pressure (1 m, free field) 
with D80/D20/D12/30D

137/133/133/133 dB

(SPLmax peak, pink noise test signal with crest factor of 4)

Vi-GSUB loudspeaker

Nominal impedance

8 ohms

Power handling capacity (RMS/peak 10 ms)

800/3200 W

Components

1 x 18“ driver
1 x 12“ driver

Connections

2 x NLT4 F/M

optional 2 x NL4 M or 2 x EP5

Pin assignment

NLT4 F/M and NL4 M: 2+ / 2–

EP5: 3: + / 4: –

Weight

61 kg (135 lb)

Vi-GSUB frequency response, standard and 100 Hz mode

 

d&b Vi-GSUB Manual 1.1 en

8

Содержание Vi-GSUB

Страница 1: ...V Vi GSUB Manual 1 1 en ...

Страница 2: ...nce When reselling this product hand over this manual to the new owner If you supply d b products please draw the attention of your customers to this manual Enclose the relevant manuals with the systems If you require additional manuals for this purpose you can order them from d b d b audiotechnik GmbH Eugen Adolff Strasse 134 D 71522 Backnang Germany T 49 7191 9669 0 F 49 7191 95 00 00 docadmin d...

Страница 3: ... loudspeaker 5 2 1 Product description 5 2 2 Connections 5 2 3 Operation 7 2 3 1 Controller settings 8 2 4 Technical specifications 8 3 Manufacturer s declarations 10 3 1 EU conformity of loudspeakers CE symbol 10 3 1 1 WEEE Declaration Disposal 10 Contents d b Vi GSUB Manual 1 1 en 3 ...

Страница 4: ...ies as detailed in our specific Mounting instructions or in our Flying system and Rigging manuals Ensure that all additional hardware fixings and fasteners used for installation or mobile deployment are of an appropriate size and load safety factor Pay attention to the manufacturers instructions and to the relevant safety guidelines Regularly check the loudspeaker housings and accessories for visi...

Страница 5: ...ystem and greatly reduces the excitation of the reverberant field at low frequencies providing the greatest accuracy of low frequency reproduction The subwoofers can be used as stand alone solutions or in stacked combinations with a minimum distance of 60 cm 2 ft between adjacent cabinets or between the subwoofers and a side wall When positioned in front of walls the minimum distance to rear walls...

Страница 6: ...tch is therefore independent of the connector type used Fixed cable connection The Vi GSUB loudspeaker is supplied with a cover plate 1 and a rubber grommet feed through 2 For indoor operation these items can be used to hide the connector panel if required For unprotected outdoor operation the connector panel must be covered i e both items must be used to achieve an IP degree of protection of IP34...

Страница 7: ...uipped with two knockout openings to allow daisy chaining of the loudspeaker To use the NL4 connection proceed in the same manner as described in the previous section 2 3 Operation NOTICE Only operate d b loudspeakers with a correctly configured d b amplifier otherwise there is a risk of damaging the loudspeaker components Application Setup Cabinets per channel Vi GSUB V GSUB 2 Within applicable d...

Страница 8: ...abinets operated in CUT mode 2 4 Technical specifications Vi GSUB system data Frequency response 5 dB standard 37 Hz 115 Hz Frequency response 5 dB 100 Hz mode 37 Hz 95 Hz Max sound pressure 1 m free field with D80 D20 D12 30D 137 133 133 133 dB SPLmax peak pink noise test signal with crest factor of 4 Vi GSUB loudspeaker Nominal impedance 8 ohms Power handling capacity RMS peak 10 ms 800 3200 W C...

Страница 9: ...Vi GSUB cabinet dimensions in mm inch d b Vi GSUB Manual 1 1 en 9 ...

Страница 10: ...respective EC directives including all applicable amendments A detailed declaration is available on request and can be ordered from d b or downloaded from the d b website at www dbaudio com 3 1 1 WEEE Declaration Disposal Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Please dispose of this product according to the respec...

Страница 11: ......

Страница 12: ...D2725 EN 01 08 2015 d b audiotechnik GmbH www dbaudio com ...

Отзывы: