2.3.1. Controller settings
For acoustic adjustment the 100 Hz function can be selected.
100 Hz circuit
If the 100 Hz circuit is selected, the upper operating frequency of
the system is reduced from 115 Hz to 95 Hz.
It can be used when actively driven Vi-GSUBs are used to
supplement V-Point cabinets operated in full range mode. The
100 Hz mode can also be used to compensate for the effect of
close coupling between the Vi-GSUB and V-Point cabinets
operated in CUT mode.
2.4. Technical specifications
Vi-GSUB system data
Frequency response (–5 dB standard)
37 Hz - 115 Hz
Frequency response (–5 dB 100 Hz mode)
37 Hz - 95 Hz
Max. sound pressure (1 m, free field)
with D80/D20/D12/30D
137/133/133/133 dB
(SPLmax peak, pink noise test signal with crest factor of 4)
Vi-GSUB loudspeaker
Nominal impedance
8 ohms
Power handling capacity (RMS/peak 10 ms)
800/3200 W
Components
1 x 18“ driver
1 x 12“ driver
Connections
2 x NLT4 F/M
optional 2 x NL4 M or 2 x EP5
Pin assignment
NLT4 F/M and NL4 M: 2+ / 2–
EP5: 3: + / 4: –
Weight
61 kg (135 lb)
Vi-GSUB frequency response, standard and 100 Hz mode
d&b Vi-GSUB Manual 1.1 en