XSL Array assembly - Preassembly
4.1.2 Secondary safety
The XSL Flying frame is equipped with two safety points
[5] fitted
with two 3.25 t shackles to accept a secondary safety device.
For this purpose, use the d&b Z5775 Safety chain which is
supplied with the flying frame or an appropriate equivalent
according to the specifications which are defined in
Chapter 3.6 "Z5775 Safety chain 2 t" on page 15.
Assembly
1. Before attaching the safety device, ensure the two 3.25 t
shackles
[S] are properly fitted to the frame's safety points [5]
and secured against loosening using a locked ring cotter
[R],
as shown in the graphic opposite.
2. Attach the safety chain set and ensure the chains are not
twisted and the hooks
[H] are in the right direction, as shown
in the graphic opposite.
4.1.3 Connecting the d&b ArraySight sender unit
WARNING!
Potential risk of personal injury.
Please observe the safety instructions provided in the ArraySight
manual.
Þ
Connect the ArraySight sender unit using the enclosed d&b
K6006.200.00 CAT5e 1:1 cable
[8b] and perform a basic
test of the laser unit.
For this purpose, the SL-Series flying frames are equipped with
a dedicated etherCON connector socket which is directly
accessible on the frame to allow for easy connection, as
shown in the graphic opposite.
↳For detailed information on the d&b ArraySight laser
inclinometer system, please refer to the ArraySight manual
which is also provided with the SL-Series flying frames.
d&b XSL Rigging manual 1.1 en
- preliminary -
27