INSTALLATION INSTRUCTIONS
CHECK MICROWAVE ASSEMBLY
Exhaust Adaptor (absent
on models shipped for
recirculation exhaust)
Back of
Microwave
• Place the microwave in its upright position, with the top
of the unit facing up.
• The microwave oven may be shipped assembled for
top exhaust (adaptor installed) or for recirculation
exhaust (adaptor absent).
• If the microwave was shipped for recirculation exhaust,
skip to C5. If shipped for top exhaust, proceed with C4.
C3
C4
ADAPTING MICROWAVE
BLOWER FOR RECIRCULATION
1
Remove tape securing damper.
2
Raise damper flap
3
Slip the damper
out of the track
on the blower
frame by pressing
and twisting
both ends.
Back of Microwave
4
Remove the screw that holds the blower plate
to the microwave. Remove and save the screw
holding the blower motor to the microwave.
Blower Plate
Blower Motor
Screw
Back of
Microwave
NOTE:
The blower plate will be reinstalled in a
later step. The damper is not needed for recirculating
models. Save any unused parts for possible future use.
5
Carefully pull out the blower unit. The wires
will extend far enough to allow you to adjust the
blower unit.
6
Roll the blower unit 90° so that fan blade openings
are facing toward the front of the microwave.
AFTER: Fan Blade
Openings Facing
Forward
Roll
BEFORE: Fan Blade
Openings Facing Up
NOTE:
Make sure wires remain routed in the grooves of
the motor frame.
20