BE SURE LEVER IS IN THE ON POSITION WHEN INSTALLATION IS COMPLETE
a.
Install an external manual gas shut-off valve to gas supply line in an easily accessible location outside of the range. Be sure
you know and where to shut-off the gas supply to the range.
b.
Install ½” flare union adapter to pressure regulator.
c.
Attach appliance conduit to flare union on regulator.
d.
Install flare union adapter to external manual shut-off valve.
e.
Attach appliance conduit to flare union on shut-off valve.
f.
Make sure service shut-off on pressure regulator is in ON position.
g.
Check for leaks. Turn the gas supply on to the range and use a liquid leak detector at the joints and conduits to check for
leaks in the system.
WARNING
Do not use a flame to check for gas leaks.
Checking manifold Gas Pressure
Disconnect the range and its individual shut-off valve from the gas supply piping system during any pressure testing of that
system at test pressures greater than 14” of water column pressure (approximately ½” psig)
The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any
pressure testing of the gas supply piping system at test pressures equal to or less than 14” of water column pressure
(approximately ½” psig)
If it should be necessary to check the manifold gas pressure, connect monometer (water gauge) or other pressure device to the
top burner right rear orifice. Using a rubber hose with inside diameter of approximately ¼”, hold tubing down tight over
orifice. Turn burner valve on.
For an accurate pressure check have at least 2 other top burner burning. Be sure the gas supply (inlet) pressure is at least one
inch above specified range manifold pressure. The gas supply pressure should never be over 14” water column. When properly
adjusted for Natural Gas the manifold pressure is 4” (For LP/Propane Gas the manifold pressure is 10”)
7. Read electrical connection details below and connect electricity to range
WARNING
Before servicing, disconnect electrical supply at circuit breaker, fuse or power cord.
Electric requirements:
An individual properly grounded and polarized branch circuit protected by 15 amp. Circuit breaker or time delay fuse. See
serial plate for proper voltage.