Installation Instructions
Fig. 1
INSTALLATION
HARDWARE
LOCATION
A)
This room air conditioner is designed to fit easily into a single or double
hung window. However, since window designs vary, it may be
necessary to make some modifications for safe, proper installation.
B)
Make sure window and frame are structurally sound and free from dry
and rotted wood.
C)
For maximum efficiency, install the air conditioner on a side of the
house or building which favours more shade than sunlight. If the unit is
in direct sunlight, it is advisable to provide an awning over the unit.
D)
Provide sufficient clearance around the cabinet to allow for ample air
circulation through the unit
(See Fig. 2)
. The rear of the unit should be
outdoors and not in a garage nor inside a building. Keep unit as far
away as possible from obstacles/obstructions and at least 30” above
the floor or ground. Curtains and other objects within a room should be
prevented from blocking the air flow.
E)
Be certain the proper electrical outlet is within reach of the installation.
Use only a single outlet circuit rated at 15 amps. All wiring should be in
accordance with local and national electrical codes.
F)
DO NOT install unit where leakage of combustible gas is suspected.
Your air conditioner may fail to operate in air containing oils (including
machine oils), sulfide gas, near hot springs, etc.
NOTE:
Your unit is designed to evaporate condensation under normal
conditions. However, under extreme humidity conditions, excess conden-
sation may cause basepan to overflow to the outside. The unit should be
installed where condensation run-off cannot drip on pedestrains or neigh-
boring properties.
5
3/4in. (19.1mm)
screws (7)
Safety Lock (1)
3/8in. (9.5mm) screws
(4) *Factory installed
on some models
“L” Shaped
mounting
bracket (1)
* Factory installed
on some models
Sash bracket (2)
Adhesive
Foam Seal(1)
Side Curtain LH (1)
Side Curtain RH (1)