background image

CLEANING:

When cleaning the air conditioner, be sure to turn the

SELECTOR

knob to the

OFF

position and 

disconnect the power cord from the electrical outlet. 

1) DO NOT

use gasoline, benzene, thinner, or any

other chemicals to clean this unit, as these 
substances may cause damage to the finish and
deformation of plastic parts. 

2)

Never attempt to clean the unit by pouring water

directly over any of the surface areas, as this will
cause deterioration of electrical components and
wiring insulation.

AIR FILTER:

If the air filter becomes clogged with dust, air flow is
obstructed and reduces efficiency. The air filter
should be cleaned every 2 weeks.

AIR FILTER REMOVAL:

The air filter is located behind the air intake front
grill. To remove the air filter, grasp the sides of the
front grill and pull forward to open and access the 
filter.

To reinstall the air filter, reverse the above 
procedures. The air filter may be vacuumed or
washed by hand in warm water. Dry thoroughly
before re-installing. 

CLEANING AIR FILTER:
1)

Use a vacuum cleaner with soft brush attachment

2) 

Wash the filter in lukewarm water below 40°C

(104°F): To get best results, wash with soapy water
or a neutral cleaning agent. 

3)

Rinse the filter with clean water and dry 

thoroughly before re-installing. 

IMPORTANT: DO NOT

forget to install the

air filter. If the air conditioner is left to operate 
without the air filter, dust is not removed from the
room air and may result in machine failure. When the
air inlet grill and cabinet are dirty, wipe with 
lukewarm water (below 40°C). Use of a mild 
detergent is recommended. 

END OF SEASON CARE:
1)

Operate the fan alone for half a day to dry out the

inside of the unit.

2)

Turn off power and remove plug from wall socket. 

3)

Clean filter.

4)

Store (covered) air conditioner in a dry location.

CAUTION: When installing and/or removing

the air conditioner from the window, ensure that
caution is taken to prevent it from falling 
backward. It is recommended that installation or
removal of the air conditioner is done with 
assistance to prevent injury to persons or damage
to the unit or property. 

CARE AND MAINTENANCE

8

Содержание DAC10010E

Страница 1: ...doit tre inclus avec l appareil CAUTION Read and follow all safety rules and operating instructions before first use of this product MISE EN GARDE Veuillez lire attentivement les consignes de s curit...

Страница 2: ...rough the wall installation For easy reference may we suggest you attach a copy of your sales slip receipt to this page along with the following information located on the manufacturers nameplate on t...

Страница 3: ...wall outlet must match the 3 prong plug on the service cord supplied with the unit DO NOT use plug adapters See Table 2 for receptacle and fuse information If it is necessary to use an extension cord...

Страница 4: ...talling or servicing 3 4 19 1mm screws 9 Factory installed on some models Safety Lock 1 Adhesive Foam Seal 1 Sash bracket 2 L Shaped mounting bracket 1 INSTALLATION HARDWARE Your Room Air Conditioner...

Страница 5: ...tain the proper electrical outlet is within reach of the installation Use only a single outlet circuit rated at 15 amps All wiring should be in accordance with local and national electrical codes F DO...

Страница 6: ...each side and secure the top of the frames to the window sash using one 3 4 screw on each side and one in the L shaped mounting bracket Fig 5 Secure the shutter clamp on each side of the lower shutter...

Страница 7: ...ration SLEEP MODE When activated the current set temperature is gradually increased over a one 1 hour period then maintained for seven 7 hours Once the program is complete the air conditioner will res...

Страница 8: ...nds in order to set the clock Press the increase or decrease arrow to adjust the clock in 1 minute intervals holding down the increase or decrease arrow will adjust the time in 10 minute intervals 10...

Страница 9: ...Dry thoroughly before re installing CLEANING AIR FILTER 1 Use a vacuum cleaner with soft brush attachment 2 Wash the filter in lukewarm water below 40 C 104 F To get best results wash with soapy water...

Страница 10: ...inappropriate for application Blocked air flow Power interruption settings changed too quickly or compressor overload tripped Clean replace air filter Check with dealer to determine proper unit capac...

Страница 11: ...de l appareil Inscrivez les renseignements suivants fournis sur la plaque signal tique du fabricant sur le c t droit de l appareil au dessus du cordon d alimentation Vous aurez besoin de ces renseigne...

Страница 12: ...ien qualifi 5 La prise murale doit correspondre la fiche 3 broches sur le cordon de service fourni avec l appareil N utilisez PAS de fiches d adaptation Voir Tableau 2 pour les renseignements sur les...

Страница 13: ...droit ce c t est plus lourd et plus difficile manipuler Un soutien inappropri du c t des commandes de l appareil peut causer des blessures et endommager l appareil et d autres biens mobiliers C est po...

Страница 14: ...pi ce puissent bloquer le flux d air E Assurez vous que la prise lectrique appropri e se trouve la port e de l installation N utilisez qu un circuit prise unique calcul 15 amp res Tout le c blage doi...

Страница 15: ...s volets compl tement de chaque c t et fixez le haut des structures au cadre de la fen tre en utilisant une vis de 3 4 po et une rondelle de s curit sur chaque c t Fig 5 Coupez la bande mousse adh sif...

Страница 16: ...meil Le mode de sommeil augmentera votre temp rature de climatisation pr r gl e graduellement pendant une p riode de un 1 heures la nouvelle temp rature est maintenue pendant sept 7 heures Une fois qu...

Страница 17: ...et la t l commande pourrait causer une interf rence au signal ce qui limiterait la capacit de programmation de l unit principale Affichage lectronique 17 7 Annuler le programme Minutrie en Marche et...

Страница 18: ...lisez un aspirateur de poussi re muni d une brosse douce 2 Lavez le filtre dans de l eau ti de de moins de 40 C 104 F Pour obtenir de meilleurs r sultants lavez avec une eau savonneuse ou un agent neu...

Страница 19: ...ement ou compresseur d clench par surcharge Nettoyez ou remplacez le filre air Verifiez avec le concessionnaire si la capacit de l appareil est appropri e son application Enlevez l objet qui obstrue l...

Страница 20: ...you call the TOLL FREE NUMBER When requesting service or ordering parts always provide the following information Product Type Model Number Part Number Part Description CLIMATISEUR Le num ro de mod le...

Отзывы: