INSTALLATION (cont’d)

3) Completing the Installation

• Cut the foam (non adhesive) sealing strip to fit the area of the

window sill that the air conditioner will rest on. 

• Carefully place the air conditioner into the window with the

“L” shaped mounting bracket (on top) 
positioned in front of the upper window sash. The bottom of
the cabinet should be positioned on the “recessed” portion of
the window frame. Pull the window down until it rests just
behind the front flange of the (top) “L” shaped mounting
bracket (See Fig. 5).

• Expand the shutter frames (fully) on each side and secure the

top of the frames to the window sash using one 3/4” screw on
each side and one in the “L” shaped mounting bracket (Fig. 5).

• Secure the shutter clamp on each side of the (lower) shutter

and secure to window sill using one 3/4” screw on each side
(Fig. 5).

• Place the second foam sealing strip to fit the opening between

the inside and outside windows, then attach the safety lock to
the outside window frame using one 3/4” screw (See Fig. 6).

Window sash

“L” Shaped

Mounting

Bracket

Shutter clamps

3/4” screws

Fig. 5

Safety Lock

3/4” screw

Foam Seal

Fig. 6

PLEASE NOTE:

Window applications come in a variety of

different styles. Therefore, it may be necessary to modify or
improvise your particular installation. 

INSTALLATION

INSTRUCTIONS (cont’d)

5

Содержание DAC10010E

Страница 1: ...doit tre inclus avec l appareil CAUTION Read and follow all safety rules and operating instructions before first use of this product MISE EN GARDE Veuillez lire attentivement les consignes de s curit...

Страница 2: ...rough the wall installation For easy reference may we suggest you attach a copy of your sales slip receipt to this page along with the following information located on the manufacturers nameplate on t...

Страница 3: ...wall outlet must match the 3 prong plug on the service cord supplied with the unit DO NOT use plug adapters See Table 2 for receptacle and fuse information If it is necessary to use an extension cord...

Страница 4: ...talling or servicing 3 4 19 1mm screws 9 Factory installed on some models Safety Lock 1 Adhesive Foam Seal 1 Sash bracket 2 L Shaped mounting bracket 1 INSTALLATION HARDWARE Your Room Air Conditioner...

Страница 5: ...tain the proper electrical outlet is within reach of the installation Use only a single outlet circuit rated at 15 amps All wiring should be in accordance with local and national electrical codes F DO...

Страница 6: ...each side and secure the top of the frames to the window sash using one 3 4 screw on each side and one in the L shaped mounting bracket Fig 5 Secure the shutter clamp on each side of the lower shutter...

Страница 7: ...ration SLEEP MODE When activated the current set temperature is gradually increased over a one 1 hour period then maintained for seven 7 hours Once the program is complete the air conditioner will res...

Страница 8: ...nds in order to set the clock Press the increase or decrease arrow to adjust the clock in 1 minute intervals holding down the increase or decrease arrow will adjust the time in 10 minute intervals 10...

Страница 9: ...Dry thoroughly before re installing CLEANING AIR FILTER 1 Use a vacuum cleaner with soft brush attachment 2 Wash the filter in lukewarm water below 40 C 104 F To get best results wash with soapy water...

Страница 10: ...inappropriate for application Blocked air flow Power interruption settings changed too quickly or compressor overload tripped Clean replace air filter Check with dealer to determine proper unit capac...

Страница 11: ...de l appareil Inscrivez les renseignements suivants fournis sur la plaque signal tique du fabricant sur le c t droit de l appareil au dessus du cordon d alimentation Vous aurez besoin de ces renseigne...

Страница 12: ...ien qualifi 5 La prise murale doit correspondre la fiche 3 broches sur le cordon de service fourni avec l appareil N utilisez PAS de fiches d adaptation Voir Tableau 2 pour les renseignements sur les...

Страница 13: ...droit ce c t est plus lourd et plus difficile manipuler Un soutien inappropri du c t des commandes de l appareil peut causer des blessures et endommager l appareil et d autres biens mobiliers C est po...

Страница 14: ...pi ce puissent bloquer le flux d air E Assurez vous que la prise lectrique appropri e se trouve la port e de l installation N utilisez qu un circuit prise unique calcul 15 amp res Tout le c blage doi...

Страница 15: ...s volets compl tement de chaque c t et fixez le haut des structures au cadre de la fen tre en utilisant une vis de 3 4 po et une rondelle de s curit sur chaque c t Fig 5 Coupez la bande mousse adh sif...

Страница 16: ...meil Le mode de sommeil augmentera votre temp rature de climatisation pr r gl e graduellement pendant une p riode de un 1 heures la nouvelle temp rature est maintenue pendant sept 7 heures Une fois qu...

Страница 17: ...et la t l commande pourrait causer une interf rence au signal ce qui limiterait la capacit de programmation de l unit principale Affichage lectronique 17 7 Annuler le programme Minutrie en Marche et...

Страница 18: ...lisez un aspirateur de poussi re muni d une brosse douce 2 Lavez le filtre dans de l eau ti de de moins de 40 C 104 F Pour obtenir de meilleurs r sultants lavez avec une eau savonneuse ou un agent neu...

Страница 19: ...ement ou compresseur d clench par surcharge Nettoyez ou remplacez le filre air Verifiez avec le concessionnaire si la capacit de l appareil est appropri e son application Enlevez l objet qui obstrue l...

Страница 20: ...you call the TOLL FREE NUMBER When requesting service or ordering parts always provide the following information Product Type Model Number Part Number Part Description CLIMATISEUR Le num ro de mod le...

Отзывы: