In General
!
Check all installation wiring carefully for wiring errors or poor connections.
Check to see that the proper voltage levels are being supplied to the unit.
Be sure that the motor is a correct model for use with this unit.
Specifically
IF MOTOR DIRECTION IS REVERSED, Check For:
Reversed connections to the Motor Connector. Reversing the phase A
or
the
phase B connections reverses the direction of motor rotation.
IF THE MOTOR MOTION IS ERRATIC, Check For:
Supply voltage out of tolerance.
Improper motion parameters (low speed, acceleration/deceleration, jog speed,
home speed and feed rate). Set parameters on controller supplying pulse input to
drive.
Filter capacitor missing or too low in value.
IF TORQUE IS LOW, Check For:
All Windings Off active.
Correct current setting.
Improper supply voltage.
IF "FAULT" INDICATOR IS LIT, Check For:
Improper motor wiring
Grounded or shorted wiring to the motor or shorted motor
Improper motor type or incorrect Current Select switch setting
If a malfunction occurs that cannot be corrected by making the preceding
checks, contact Customer Support.