background image

7

ADJUSTMENT OF AIR SPEED AND TEMPERATURE 

• Insert a flat notch through the hole in the bottom of the casing and place it in the 
  potentiomenter screw (see drawing below).

 

• Adjust the air speed and temperature by rotating the potentiomenter screw: 
  Clockwise to in). 
  Counterclockwise to decrease (-). 
 

Note

: Do not overturn the adjustment!

SENSOR RANGE ADJUSTMENT 

 

The sensor range is adjustable between 100mm og 230mm  

Standard range 170mm ± 20mm 

 
• Switch off the power, remove the (2) screws in the lower area, and remove the cover. 
• Use a small Phillips screw driver or flat notch to adjust the sensoren on the VR-screw: 
   Clockwise: To increase sensor activation range (+) 
  Counterclockwise: To decrease sensor activation range (-) 
• The sensor activation range should be adjusted to its environments,  
   e.g. light and distance to the bottom of the sink. 

Note

: Do not overturn the sensivity adjustment.

 

Содержание BJORK 3000

Страница 1: ...USER MANUAL BJ RK HAND DRYER Model 3000 3002 3006 3010 3012 3016...

Страница 2: ...turned to the manufacturer retailer for proper treatment recovery and recycling Dimensions and technical specifications 3 General safety information 4 Circuit diagram 4 Installation 5 User guide 6 Rec...

Страница 3: ...range 100 230 mm adjustable Standard 170mm 20mm Protection timer 60 seconds auto shut off IP Class IP31 Insulation class Class 1 Net weight 5 7 kg Gross weight 6 5 kg PRODUCT TYPE MODEL 3000 3010 Whi...

Страница 4: ...asin tabletop or other surface This product is suitable for indoor use only Type Y connection If the power supply cord is damaged it must be replaced immediately Only qualified persons shall be permit...

Страница 5: ...5 Connect supply wires to terminal block CONNECTIONS A Connect live wire coloured red or brown to the terminal block marked L B Connect neutral wire coloured blue to terminal blcok marked N C Connect...

Страница 6: ...and rapidly Stops automatically after hands are removed CLEANING AND MAINTENANCE Routine cleaning and maintenance is recommended every 12 months to ensure your hand dryer is running at optimal perfor...

Страница 7: ...NSOR RANGE ADJUSTMENT The sensor range is adjustable between 100mm og 230mm Standard range 170mm 20mm Switch off the power remove the 2 screws in the lower area and remove the cover Use a small Philli...

Страница 8: ...he breaker supplying the dryer is operational If it is disconnect the power and remove the cover Repla ce PCB and IR sensor Taking suitable precaution to avoid shock hazard reconnect the power and che...

Страница 9: ...Blower housing rubber large 9 Motor 700W 10 Blower housing rubber small 11 Heating element 900W 12 LED unit PARTS LIST No Description 13 Outlet branch 14 Sensor bracket 15 Sensor 16 Blower housing bra...

Страница 10: ...10 DAN DRYER A S Alsikevej 8 DK 8920 Randers NV T 45 8641 5711 E info dandryer dk W dandryer com...

Отзывы: