INSTALLATION

1: Remove the two screws in the lower 

area of the unit and remove the casing 

from its base.

5: Replace the casing and fasten with two

screws in the lower area

3: Connect supply wires to terminal block

4: Attach mounting plate  

securely with four screws

2: Insert the power cord through the inlet 

hole.

Connections:

A. Connect LIVE to terminal “L”

B. Connect NEUTRAL to terminal “N”

C. Connect GROUND to terminal “   “

Make sure the main breaker is turned off. Installation must be carried out by a  

qualified person in accordance with standards applicable in the country where 

 

the equipment is to be installed.

Place template against the wall at desired height (see mounting height recommendations) 
and mark location of (4) mounting holes and the wire service entry.

Note

: If several products are installed in close proximity to each other, the minimum 

distance between the products should be 610 mm from the centerline of each product.

Содержание 346-347-348

Страница 1: ...USER MANUAL TURBO LOW NOISE HAND DRYER Model 346 347 348 250 251 254...

Страница 2: ...rm air speed output 7 Heating element switch 7 Adjustment of sensor range 7 Troubleshooting and corrective actions 8 Symptoms and corrective actions of first time installed hand dryers 8 Symptoms and...

Страница 3: ...00W adjustable Heating element protection Auto resetting thermostat turns circuit off at 85 C thermal fuse turns off at 142 C Drying time 15 seconds Stand by power 0 3 0 4W Sensor type Infrared self a...

Страница 4: ...ion If the power supply cord is damaged it must be replaced immediately Only qualified persons shall be permitted to replace the cord to avoid a hazard Disconnect the electricity supply cord according...

Страница 5: ...NEUTRAL to terminal N C Connect GROUND to terminal Make sure the main breaker is turned off Installation must be carried out by a qualified person in accordance with standards applicable in the count...

Страница 6: ...re worn they must be replaced The estimated lifespan for carbon brushes is 580K activations Do not soak Use a damp cloth and mild cleaning solution Never use cleaning detergents with an abrasive effec...

Страница 7: ...erclockwise to decrease air speed SENSOR RANGE ADJUSTMENT The sensor range adjustable between 100mm and 230mm Standard range 170mm 20mm Clockwise To increase sensor activation range Counterclockwise T...

Страница 8: ...n First ensure that the breaker supplying the dryer is opera tional If it is disconnect the power and remove the cover Replace PCB and IR sensor Taking suitable precaution to avoid shock hazard reconn...

Страница 9: ...rubber large 6 Motor 7 Motor rubber small 8 Blower housing lower 9 Heating element 10 Air outlet 11 LED panel 12 Air outlet bracket 13 Timer with IR sensor 14 Sensor bracket 15 Rubber bushing 4 reqd...

Страница 10: ...10 DAN DRYER A S Alsikevej 8 DK 8920 Randers NV T 45 8641 5711 E info dandryer dk W dandryer com...

Отзывы: