background image

3

Dimensions
Unit of measurement: mm

TECNICAL SPECIFICATIONS

DESCRIPTION

DATA

Operating voltage

110V-120V, 50/60Hz, 10.8-11.7A, 1.19-1.4kW 

220V-240V, 50/60Hz, 5.4-5.8A, 1.19-1.4kW

Air temperature

55°C ~ ambient temperature 25°C

Air speed

65-95 m/s (adjustable)

Motor type

350-700W (adjustable) carbon brush with double ball bearings, 

12000-18000 rpm. Lifespan of carbon brushes: Approx. 580K 

activations

Motor thermal protection

Auto resetting, thermostat turns off at 135°C

Heating element

350 - 700W (adjustable)

Heating element protection

Auto resetting, thermostat turns circuit off at: 85°C,  

thermal fuse turns off at 142°C 

Drying time

≤ 15 seconds

Stand-by power

0.3-0.4W

Sensor type

Infrared, self adjusting

Sensor range

100-230 mm adjustable. Standard 170mm± 20mm

Protection timer

60 seconds auto shut off

IP Class

IP31 or IP33 (option)

Insulation class

Class 1

Net weight

5.5 kg

Gross weight

6.1 kg

PRODUCT TYPE / MODEL

346 / 250   White enamel coated steel, Turbo Low Noise hand dryer, 230V/110V  
347 / 251   Stainless steel, brushed, Turbo Low Noise hand dryer, 230V/110V 
348 / 254   Black powder coated stainless steel, Turbo Low Noise hand dryer, 230V/110V

DIMENSIONS AND TECHNICAL SPECIFICATIONS

Содержание 346-347-348

Страница 1: ...USER MANUAL TURBO LOW NOISE HAND DRYER Model 346 347 348 250 251 254...

Страница 2: ...rm air speed output 7 Heating element switch 7 Adjustment of sensor range 7 Troubleshooting and corrective actions 8 Symptoms and corrective actions of first time installed hand dryers 8 Symptoms and...

Страница 3: ...00W adjustable Heating element protection Auto resetting thermostat turns circuit off at 85 C thermal fuse turns off at 142 C Drying time 15 seconds Stand by power 0 3 0 4W Sensor type Infrared self a...

Страница 4: ...ion If the power supply cord is damaged it must be replaced immediately Only qualified persons shall be permitted to replace the cord to avoid a hazard Disconnect the electricity supply cord according...

Страница 5: ...NEUTRAL to terminal N C Connect GROUND to terminal Make sure the main breaker is turned off Installation must be carried out by a qualified person in accordance with standards applicable in the count...

Страница 6: ...re worn they must be replaced The estimated lifespan for carbon brushes is 580K activations Do not soak Use a damp cloth and mild cleaning solution Never use cleaning detergents with an abrasive effec...

Страница 7: ...erclockwise to decrease air speed SENSOR RANGE ADJUSTMENT The sensor range adjustable between 100mm and 230mm Standard range 170mm 20mm Clockwise To increase sensor activation range Counterclockwise T...

Страница 8: ...n First ensure that the breaker supplying the dryer is opera tional If it is disconnect the power and remove the cover Replace PCB and IR sensor Taking suitable precaution to avoid shock hazard reconn...

Страница 9: ...rubber large 6 Motor 7 Motor rubber small 8 Blower housing lower 9 Heating element 10 Air outlet 11 LED panel 12 Air outlet bracket 13 Timer with IR sensor 14 Sensor bracket 15 Rubber bushing 4 reqd...

Страница 10: ...10 DAN DRYER A S Alsikevej 8 DK 8920 Randers NV T 45 8641 5711 E info dandryer dk W dandryer com...

Отзывы: