![damian LXS9 Series Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/damian/lxs9-series/lxs9-series_installation-and-service_3330072039.webp)
Serie "LXS9"
Pagina A - 17
Rev. M - 01
Where “
xxxxxx
” is the detected error. See the “
Installation and service
” manual, "
Problems and relative
solutions
” chapter, “
Motor anomaly messages
” section for the list of anomalies and relative solutions.
It is important to keep in mind that even possible out of orders that are automatically reset (R) by turning
the vending machine on and off are also listed in this menu (see “
Motor anomaly messages
" chapter
indicated above). The indication remains until the out of order has been reset as indicated below.
Press the
C
key to cancel the Out of Service condition of the current motor. The following message will
appear on the display:
Press the
A
key to exit the submenu.
NOTE:
It is possible to cancel all of
the “Out of Order” conditions of the motors without entering into
programming by pressing the PS2 key found on the CPU card for approx. 3 seconds (See Page A-2).
>
M
ANUAL MOTOR TEST
:
Select this item to test the individual motors, making them carry out a sales cycle.
Use the
D
and
E
keys to scroll through all of the motors detected during the self-learning procedure.
When the
F
key is pressed briefly, the current motor will be activated; the following message will appear if
a malfunction occurs:
Where “
xxxxxx
” is the detected error. See the “
Installation and service
” manual, "
Problems and relative
solutions
” chapter, “
Motor anomaly messages
” section for the list of anomalies and relative solutions.
The general test cycle will begin instead when the
F
key is kept press for about one second; during this
cycle, the vending machine will carry out a sales cycle in sequence for each gearmotor detected by the
self-learning procedure, starting from the current motor up to the last motor of the vending machine. In the
event of a defect on one of the motors, the test will be interrupted and the relative error message
displayed.
The general test cycle will be interrupted when keeping any key pressed until the end of the sales cycle of
the current motor.
Press the
A
key to exit the submenu.
>
M
OTOR
V
ERIFY
:
Select this item to perform a quick check of the condition of the motors.
This function does not change the vending machine configuration detected during the self-learning
procedure; it simply limits itself to comparing the current condition of the motors with that of the last self-
learning procedure performed.
[Where x.x scrolls the motors in sequence]
Motor : x.x
Reset
Error
xxxxxx
Programming
Diagnostics
Mot Manual Test
->->->->
Motor : x.x
F
F
Programming
Diagnostics
Motor Verify
->->->->
Motor : x.x
F
F
Содержание LXS9 Series
Страница 2: ...Serie LXS9 Pagina A 25 Rev M 01...
Страница 22: ...Serie LXS9 Page 21 Rev M 01...